60
−
6 F 8 A 0 9 3 4
COUNT
: displays the totalized flow counts (up to 8 digits).
RANGE
: displays the range number being used for measurement (1 to 4).
GPARH
: displays the measured value (% value) in bar graph.
In addition, the range number being used for measurement is also displayed.
CUSTOM
: displays the result obtained by multiplying m
3
/min by the custom coefficient.
The details see
10.10 “Custom unit function”
.
Note 2:
GRAPH
display can be selected only for Display 2 screen.
For display settings, Display 1 (
DSPL1
) and Display 2 (
DSPL2
) can be set independently.
The following is an example to change the Display 1 setting from
%
to
mL/s
.
Switch operation
Display example
Description
B:DISPLAY
1 DSPL1
2 DSPL2
3 CS VAL
4 CS UNIT
5 EXIT
Select "
DSPL1
" from the setting item
selection menu.
STEP1
DSPL1
%
The currently set display setting
(%
in this
example) appears.
Then push .
* Pushing returns you to the setting
menu.
STEP2
DSPL1
%
The switches at the bottom change.
( are shown.)
At the same time, the cursor appears.
STEP3
DSPL1
mL/
s
Push to move the cursor from the
second unit to the third unit and change the
display unit by pushing .
Repeat this operation to change the display
unit to
mL/s
.
When the desired display unit is selected,
push to set the display unit
temporarily.
STEP4(=END)
DSPL1
mL/s
SET OK?
Pushing shows a message to confirm
whether the setting is
OK
or not.
If
OK
, push . If you need to redo
the setting, push .
Pushing cancels the setting
operation and exits the setting screen.
Note 1: The first unit (volumetric units etc.) changes as shown below:
% m
3
L mL bbl gal m/s ft/s
GRAPH CUSTOM qt pt RANGE COUNT
Note 2: The second unit (time unit) changes as shown below:
N O
O K
ESC
ESC
ESC
ESC
O K
N O
ESC
Содержание LF516