53
2.2.7.
Fuser Unit
CAUTION:
To prevent from getting burned, do not install, remove, clean or make adjustments when the Fuser Unit is
hot.
(1) Remove the
Inner Cover Assembly
. (Refer to
2.2.6.)
(2) Disconnect 2
Harnesses
by pressing down on
the connector latches with a small screw driver.
(3) Open the
Rear Cover
.
(4) Remove 4
Screws
(T9).
(5) Remove the
Upper Exit Roller Holder
(1201).
(6) Remove 1
Screw
(Y3).
(7) Remove the
Fuser Harness Cover
(1023).
(8) Disconnect the
Harness
on the LVPS.