126
582
XMT
B
Sub-address SEP (for Polling)
transmission to a unit that has their
DIS bit 47 (NSF bit 130) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
601
XMT
ADF Door was opened during ADF
transmission.
623
XMT
A
No original was in the ADF. (Built-
in dialer engaged)
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
630 XMT or RCV
(Polling)
B
Redial count over.
No dial tone detected. Sensor dial tone
is not detected. (Destination dependent)
Busy tone is detected. (Destination
dependent) T1 timer (35 ± 5 sec.)
elapsed without a signal from the
receiver.
631
XMT
A
"STOP" button was pressed during
Auto Dialing.
634
XMT
B
Redial count over with no
response or busy tone was not
detected.
Note:
U.S.A. and Canadian models
will redial only once if a busy
tone is not detected.
Telephone line cable is disconnected.
Wrong number is dialed.
SC or FXB PCB is abnormal.
638
XMT
LAN
Power turned Off with applicable
data in memory or during
communication.
Power switched off.
Power failure occurred.
700
XMT
RCV
PSTN
LAN
Communication terminated by
Operator pressing the "STOP" key.
711
RCV
LAN
Incorrect LDAP settings.
LDAP Server Name, LDAP Login
Name, LDAP Password and/or LDAP
Search Base are incorrect.
712
XMT
LAN
Unknown email address replied
from the Mail Server.
Mail Server received an incorrect email
address. (Dependent on Server's Mail
application)
714
XMT
RCV
LAN
LAN Interface error.
Cannot logon to the LAN.
The 10Base-T/100Base-TX cable is not
connected.
An unexpected LAN problem occurred.
Check the SC PCB connector.
715
XMT
LAN
TCP/IP connection timed out.
Incorrect IP Address is set.
Verify the IP Address, Default Router IP
Address, SMTP Server IP Address.
716
XMT
LAN
Cannot logon to the LAN.
Incorrect SMTP Server IP Address is
set.
No email application is activated on the
Mail Server.
717
XMT
LAN
Incomplete SMTP Protocol
transmission.
Mail Server’s hard disk may be full.
Mail Server is defective.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Содержание e-STUDIO190F
Страница 1: ...SERVICE MANUAL PLAIN PAPER FACSIMILE e STUDIO190F File No SME060019A0 R060521B7301 TTEC Ver01_2006 08 ...
Страница 5: ...5 ...
Страница 21: ...21 1 2 Control Panel For Americas e STUDIO190F ...
Страница 36: ...36 12 Remove 3 Screws Y3 13 Remove 4 Screws Y3 14 Remove the Paper Guide 452 15 Remove the CIS 440 Assembly ...
Страница 78: ...78 2nd G3 UF 8K G3B A A Vxxxxx YC Firmware Version V1xxxx AA Fixed 2nd G3 Model Number YC Fixed ...
Страница 119: ...119 Sensor and Switch Location ...
Страница 185: ...185 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 227: ...227 CN236 16 N C PNL2 PCB CN252 16 No Connection PNL1 PCB Pin No Signal Name Destination Signal Waveform Function ...
Страница 234: ...234 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Страница 297: ...297 memo ...
Страница 299: ...299 memo ...