160
070 Line Error
128 lines
256 lines
512 lines
1024 line
2048 lines
Off
(will not disconnect line)
1. Selects the line disconnect condition during
reception. If the number of line errors exceed this
setting, the unit will disconnect the line.
Press “V” or “/\ “ to select the symbol rate.
2. Selects the transmit condition of RTP/PIP or
RTN/PIN.
(Available if No.73 Error Detect is set to "LINES")
(See Note 1)
071 Total Error
1 = 5%
2 = 10%
3 = 15%
4 = 20%
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
072 Continuous Error 1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
Selects the continuous total error criteria of Off/3/6
or 12 lines in Standard mode. If continuous total
error exceeds this setting, the unit will transmit
RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
073 Error Detect
1 = Lines
2 = Rate
Selects the error detect condition Lines/Rate.
074 RTN Receive
1 = Disconnect
2 = Continue
Selects whether to disconnect the phone line or
continue when "RTN" is received.
075 Coding
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
4 = JBIG
Selects the coding scheme.
076 Batch TX
1 = Off
2 = On
Selects whether the batch transmission is available.
077 RX JAM Length
1 = Off (unlimited)
2 = 2 m
Selects the maximum length of a received
document that can be printed.
078~
079
Not Used
080 Doc Top Feed
-99
~
+99
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
081 Doc End Feed
-90
~
+127
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
082 JAM Length
1 = 1 m
2 = 2 m
Selects the maximum length of the original that can
be scanned.
083 Not Used
084 Line As No Paper 1 = Ring (ring)
2 = Busy (keep line busy)
Selects whether to ring or send a busy tone to the
remote station when the recording paper runs out or
the unit cannot receive because of any trouble.
085~
086
Not Used
087 Darker Level
0 = Lightest Contrast
~
15 = Darkest Contrast
Selects the contrast level.
0
←
→
15
Lightest
←
→
Darkest
088 Normal Level
089 Lighter Level
Function Parameter Table
No.
Parameter
Selections
Function
Содержание e-STUDIO190F
Страница 1: ...SERVICE MANUAL PLAIN PAPER FACSIMILE e STUDIO190F File No SME060019A0 R060521B7301 TTEC Ver01_2006 08 ...
Страница 5: ...5 ...
Страница 21: ...21 1 2 Control Panel For Americas e STUDIO190F ...
Страница 36: ...36 12 Remove 3 Screws Y3 13 Remove 4 Screws Y3 14 Remove the Paper Guide 452 15 Remove the CIS 440 Assembly ...
Страница 78: ...78 2nd G3 UF 8K G3B A A Vxxxxx YC Firmware Version V1xxxx AA Fixed 2nd G3 Model Number YC Fixed ...
Страница 119: ...119 Sensor and Switch Location ...
Страница 185: ...185 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 227: ...227 CN236 16 N C PNL2 PCB CN252 16 No Connection PNL1 PCB Pin No Signal Name Destination Signal Waveform Function ...
Страница 234: ...234 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Страница 297: ...297 memo ...
Страница 299: ...299 memo ...