97
9.5.30 REAR RIBBON MOTOR
The menu structure of REAR RIBBON MOTOR menu
Menu item
<2>SET PARAMETERS
REAR RIBBON MOTOR
Normal Torque
Low Torque
Reserved1 (only B-EX6T1/T3)
9.5.30.1 Normal Torque
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step
Notes:
1. The fine adjustment value is not effective for the reverse rotation.
2. The fine adjustment value for the ribbon supply motor is applicable to every print speed.
Print speed
All print speeds
Fine adjustment value
-15 to +10
3. The ribbon motor torque fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is -15 or +10.
9.5.30.2 Low Torque
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step
Notes:
1. The fine adjustment value is not effective for the reverse rotation.
2. The fine adjustment value for the ribbon supply motor is applicable to every print speed.
Print speed
All print speeds
Fine adjustment value
-15 to +10
3. The ribbon motor torque fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is -15 or +10.
9.5.30.3 Reseved1 (only B-EX6T1/T3)
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step