92
9.5.23 BACK ADJ.
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+9.9
-9.9
0.1
Decimal
Exist
1
1
None
mm
+0.0mm
+3.0mm
-3.0mm
Note:
1. The reverse feed amount fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is ±9.9mm.
Note: There may be cases where a label is not returned to the home position depending on the print
conditions, even if the media is fed backward for the same amount as the forward feed. For issuing
media with the media sensor, if the label pitch is almost the same as the distance between the print
head and the media sensor (75.5 mm), the media may not be returned to the home position when
operations including a reverse feed (such as cut issues, strip issues, automatic forward feed) are
performed. It may result in an error. To prevent this error from occurring, increase the reverse feed
amount by performing the reverse feed amount fine adjustment in the + direction.
Print start position
(Home position after a back feed)
Print start position
(Home position after a back feed)
Print start position
(Home position after a back feed)