4. SYSTEM MODE (For Service Persons and System Administrators)
EO13-33005
4.4 Parametr Setting
4- 40
4.4.18 System Mode Password Setting (PASSWORD)
This setting selects whether or not a new password, which is required to enter system mode for service
persons and system administrators, is to be programmed. (Factory default is OFF (Password is “0000”.))
Notes:
1. When the
[FEED]
key is pressed, the menu moves in the opposite direction from when the
[PAUSE]
key
is pressed.
2. When the
[FEED]
and
[PAUSE]
keys are simultaneously pressed, the display returns to the system
mode menu.
3. When the
[FEED]
key or
[PAUSE]
key is pressed for 0.5 seconds or more during this parameter setting,
repeat mode is enabled and the key pressed is repeatedly entered.
4. The change in the parameter setting becomes effective when the
[POWER]
key is pressed after setting,
then stored in the backup memory.
PASS WORD OFF----
[PAUSE]
PASS WORD ON 0000
[POWER]
Password is not set.
Password is set.
PASS WORD
0
000
[PAUSE]
PASS WORD
1
000
[PAUSE]
PASS WORD
2
000
[PAUSE]
PASS WORD
D
000
[PAUSE]
PASS WORD
E
000
[PAUSE]
PASS WORD
F
000
[POWER]
PASS WORD F
0
00
[PAUSE]
Pressing the
[POWER]
key determines a value in the current digit and
moves the cursor to the next digit. This operation is same for 3rd and
4th digits.