4. SYSTEM MODE (For Service Persons and System Administrators)
EO13-33005
4.4 Parametr Setting
4- 31
4.4.6 Control Code Setting (CODE)
This setting selects a control code to be used in TPCL mode.
Notes:
1. When the
[FEED]
key is pressed, the menu moves in the opposite direction from when the
[PAUSE]
key
is pressed.
2. When the
[FEED]
and
[PAUSE]
keys are simultaneously pressed, the display returns to the system
mode menu.
3. When the
[FEED]
key or
[PAUSE]
key is pressed for 0.5 seconds or more during this parameter setting,
repeat mode is enabled and the key pressed is repeatedly entered.
4. The change in the parameter setting becomes effective when the
[POWER]
key is pressed after setting,
then stored in the backup memory.
5. This setting is effective in TPCL and TPCL1 modes.
(1) AUTO
As an interface command control code, [ESC](1BH),[LF](0AH),[NUL](00H) or {(7BH),|(7CH),}(7DH) is
automatically selected. After the power is turned on, the data from the host is checked for [ESC] and {,
and the data sent first is assumed to be a control code.
For example, if [ESC] is sent first, [ESC].[LF].[NUL] is a control code, and if { is sent first, {.|.} is a
control code. The control code is selected for each command.
If the first command ends with [ESC]~ [LF][NUL] and is followed by [ESC], the control code is
[ESC].[LF].[NUL]. If { is sent first, the control code for the next command is {.|.}.
When the control code is {.|.}, the data of 00H to 1FH in { ~ | } is ignored.
However, the data of 00H to 1FH becomes valid while processing the graphic command or writable
character command in hexadecimal mode. When {.|.} is a control code, {.|.} cannot be used in the data
of the Data command or Display command.
CODE AUTO
CODE {,|,}
Automatic selection between {.|.} method
and ESC.LF.NUL method (Factory default)
{, |, } method
CODE ESC,LF,NUL
ESC, LF, NUL method
[PAUSE]
[FEED]