4. SYSTEM MODE (For Service Persons and System Administrators)
EO13-33005
4.8 RAM Clear
4- 70
4.8.3 Parameter Clear (PARAMETER CLEAR)
This setting is used for sensitivity adjustment of strip sensor.
Depending on destination (model type), the default value of the LCD language vary.
Notes:
1 When
the
[FEED]
key is pressed, the menu moves in the opposite direction from when the
[PAUSE]
key is pressed.
2 When
the
[FEED]
and
[PAUSE]
keys are simultaneously pressed, the display returns to the system
mode menu.
3 When
the
[FEED]
key or
[PAUSE]
key is pressed for 0.5 seconds or more during this setting, repeat
mode is enabled and the key pressed is repeatedly entered.
4.8.4 Parameter Clear Operation Example
RAM clear for Global model (QM)
Notes:
1. When “COMPLETE” is displayed after RAM clear is completed, turn off the power. (The power can be
turned off only by using the
[POWER]
key.)
2. The total label distance covered and sensor adjustment values (system mode <6>) are not cleared by
RAM clear.
*** QM TYPE ***
*** JA TYPE ***
RAM clear for Global model
RAM clear for Japan model
[PAUSE]
RAM clear for the QM type
[POWER]
*** QM TYPE ***
PARAMETER CLEAR
[POWER]
Parameter Clear Mode
*
Start of parameter clear
* *
Progress display
*** COMPLETE ***
[POWER]
Power OFF
Completion of parameter clear
* * *
* * * * * * * * * * * * * * * *
The power is turned off.