4. SYSTEM MODE (For Service Persons and System Administrators)
EO13-33005
4.2 Diagnostic Test
4- 19
SENSOR2 [H]+20
°
C [A]+22
°
C
Ambient thermistor status
(-15 °C to 99°C, --°C: if the temperature cannot be detected)
Thermal head thermistor status (-15 °C to +70 °C)
[R]4.2V [T]2.5V
Transmissive sensor status (0.0V to 5.0V)
Reflective sensor status (0.0V to 5.0V)
No paper level
PE LV. [R]1.8V [T]2.5V
Transmissive sensor for no paper level (0.0V to 5.0 V)
Reflective sensor for no paper level (0.0V to 5.0 V)
BATTERY 16.8V [5]
Battery level
B-EP2 [1]: 7.2V or less
[2]: 7.3V to 7.4V
[3]: 7.5V to 7.7V
[4]: 7.8V to 7.9V
[5]: 8.0V to 8.4V
B-EP4 [1]: 14.0V or less
[2]: 14.1V to 14.6V
[3]: 14.7V to 15.2V
[4]: 15.3V to 15.8V
[5]: 15.9V to 16.8V
Battery voltage
B-EP2: 7.3V to 8.4V
B-EP4: 14.1V to 16.8V
Threshold value
M THRE. [R]1.8V [T]2.5V
Transmissive sensor for manual threshold level (0.0V to 5.0V)
Reflective sensor for manual threshold level (0.0V to 5.0 V)