XII.6 CONFIGURATION MENU OPTIONS AND DEFINITIONS
Device
Unit type
Default
Description
APuGO
Off
Off, 2°-10°
Triggering angle for Push and Go (angle Push and Go)
ASES
95°
45°-95°
Lock out angle:
Angle at which the swing side Door/Gate panel mounted sensor is ignored just
before open/
If Ao is changed, ASES is automatically set to Ao.
ASER
0°
0°-60°
Lock out angle: angle at which push side of the Door/Gate panel sensor is
ignored just before closing.
SESClo
Inactive
Active
Sensor mounted on swing side of Door/Gate is activated or inactivated during
closing cycle
Inactive
EMY-IN
CL-SPR
Configuration of the emergency terminal (break contact switch)
CL-SPR
Spring close (standard application)
STOP
Stops Door/Gate panel closing/opening
OPEN
Opens the Door/Gate panel
CL-MOT
Motor close (inverse application)
OExSTp Off
Off
N/A
❖
Used to set one of the activation “values” to “sequential”
mode.
❖
Sequential mode is used to hold the door open until a
second activation is received.
❖
One activation opens the Door/Gate panel, and a
second activation is needed to close the Door/Gate
panel.
OEI
Opening devise
inside
OEO
Opening devise
outside
KEY
Key opening
devise
RADIO
N/A
UNLOCK PERMAN
IMPULS
When the Door/Gate panel is first opened: momentarily unlocks the electric lock
PERMAN
When the Door/Gate panel is first opened: Permanently unlocks the electric
lock.
EL-FB
Off
Off
Electric lock status feedback
N.O.
Open if unlocked (-); closed if locked (+)
N.C.
Open if locked (+); closed if unlocked (-)
Lock AU UNLOCK
UNLOCK/LOCK
❖
Sets the condition of the lock when in automatic mode.
❖
Only visible when Unlock is set to PERMAN.
LockEX
LOCK
UNLOCK/LOCK
❖
Sets the condition of the lock when in EXIT mode.
❖
Only visible when Unlock is set to PERMAN
LockMA
UNLOCK
UNLOCK/LOCK
❖
Sets the condition of the lock when in MANUAL mode.
❖
Only visible when Unlock is set to PERMAN
Содержание AUTOPED M10S.0028
Страница 1: ...Autoped Installation Manual rev 2 0 100722 1 AUTOPEDTM OPERATOR INSTALLATION MANUAL 2022...
Страница 12: ...Autoped Installation Manual rev 2 0 100722 12 SECTION I INSTALLING THE AUTOPED ON HEADERS 4 OR BIGGER...
Страница 29: ...Autoped Installation Manual rev 2 0 100722 29 SECTION VI CONNECTING THE AUTOPED TO AC POWER SOURCE 115 VAC...
Страница 40: ...Autoped Installation Manual rev 2 0 100722 40 SECTION X SETTING UP ELECTRIC LOCKS AND STRIKES...
Страница 50: ...Autoped Installation Manual rev 2 0 100722 50 SECTION XII MENUS AND PROGRAMMING...
Страница 59: ...Autoped Installation Manual rev 2 0 100722 59 SECTION XIII TROUBLE SHOOTING AND ERROR CHARTS...
Страница 65: ...Autoped Installation Manual rev 2 0 100722 65 SECTION XIV TERMINAL CONNECTIONS AND WIRING SCHEMATICS...
Страница 69: ...Autoped Installation Manual rev 2 0 100722 69 Fig XIV 2b Non Powered Activation Devices...
Страница 75: ...Autoped Installation Manual rev 2 0 100722 75 Fig XIV 2f Secured Activation Devices...
Страница 76: ...Autoped Installation Manual rev 2 0 100722 76 Fig XIV 2g Wiring for Double Door Gate System...
Страница 77: ...Autoped Installation Manual rev 2 0 100722 77 SECTION XV SERVICE PARTS...
Страница 78: ...Autoped Installation Manual rev 2 0 100722 78 XV 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...
Страница 80: ...Autoped Installation Manual rev 2 0 100722 80 SECTION XVI PRODUCT WARRANTY AND REGISTRATION...