Electrical
System
Reelmaster 5500-D
Page 5 - 21
Electrical System (Rev. C)
Warning Light Cluster
Note: Individual light bulbs can be tested by removing
them from the lighting cluster and applying 14 VDC to
their wiring terminals.
Testing Cluster Removed from Connector.
1. Apply 14 VDC to pin D.
2. Ground pins F, A, and E.
3. Lamps 1, 2, and 3 should light.
4. Apply 14 VDC to pin B.
5. Ground pin C.
6. Lamp 4 should light.
Oil Pressure Light
The oil pressure light should come on when the ignition
switch is in the ON position with the engine not running.
Also, it should light with the engine running when the oil
pressure drops below 4 PSI (0.3 kg/cm
2
).
1. Disconnect green/blue wire from the oil pressure
switch.
2. Ground green/blue wire to the engine block.
3. Turn ignition switch to ON; the light should come on.
4. Turn ignition switch to OFF. Connect green/blue wire
to the oil pressure switch.
High Temperature (Water) Shutdown Light
When the coolant temperature is above 221
F (105
C),
the temperature light comes on as the high temperature
shutdown switch and Electronic Control Unit (ECU) stop
the engine.
Glow Light
The glow light comes on when the ignition switch is
placed in RUN prior to placing the ignition switch in
START, and stays light for 10 seconds while left in RUN.
Battery Light
The battery light should come on when the ignition
switch is in ON with the engine not running, or with an
improperly operating charging circuit while the engine is
running.
1. Turn ignition switch to ON; the light should come on.
2. Turn ignition switch to OFF: the light should go off.
Figure 21
A
B
C
D
E
F
2
1
4
3
1. Oil pressure (red)
2. Water temperature (red)
3. Battery
(amber)
4. Glow plugs (amber)
5. Gauge
front
6. Gauge
back
1
2
3
4
6
5
Figure 22
1
2
3
4
+14VDC
+14VDC
F
A
E
B
C
D
Содержание 00075SL
Страница 2: ...Reelmaster 5500 D ...
Страница 4: ...Reelmaster 5500 D ...
Страница 6: ...Reelmaster 5500 D ...
Страница 12: ...0 09375 Rev D Reelmaster 5500 D Page 2 2 Product Records and Maintenance Equivalents and Conversions ...
Страница 49: ...Hydraulic System Reelmaster 5500 D Hydraulic System Rev C Page 4 11 This page is intentionally blank ...
Страница 64: ...Reelmaster 5500 D Hydraulic System Rev C Page 4 26 This page is intentionally blank ...
Страница 89: ...Hydraulic System Reelmaster 5500 D Hydraulic System Rev C Page 4 51 This page is intentionally blank ...
Страница 109: ...Hydraulic System Reelmaster 5500 D Hydraulic System Rev C Page 4 71 This page is intentionally blank ...
Страница 115: ...Hydraulic System Reelmaster 5500 D Hydraulic System Rev C Page 4 77 This page is intentionally blank ...
Страница 170: ...Reelmaster 5500 D Page 5 40 Electrical System Rev C ...
Страница 192: ...Reelmaster 5500 D Differential Axle Page 6 22 ...
Страница 254: ...Reelmaster 5500 D Groomer Rev C Page 8 1 14 ...
Страница 278: ...Reelmaster 5500 D Page 10 2 Electrical Diagrams Rev C ...
Страница 284: ...Rev C Page 10 8 Harness Drawing Reelmaster 5500 D Serial Number 210000401 to 210999999 ...
Страница 285: ...Rev C Page 10 9 Harness Diagram Reelmaster 5500 D Serial Number 210000401 to 210999999 ...
Страница 286: ...Rev C Page 10 10 Harness Drawing Reelmaster 5500 D Serial Number 220000001 to 220999999 ...
Страница 287: ...Rev C Page 10 11 Harness Diagram Reelmaster 5500 D Serial Number 220000001 to 220999999 ...
Страница 288: ...Rev C Page 10 12 Harness Drawing Reelmaster 5500 D Serial Number Above 230000000 ...
Страница 289: ...Rev C Page 10 13 Harness Diagram Reelmaster 5500 D Serial Number Above 230000000 ...
Страница 290: ...Reelmaster 5500 D ...