![Tormatic TAD MS 230V Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/tormatic/tad-ms-230v/tad-ms-230v_assembly-and-operating-instructions-manual_1130441029.webp)
EN - 27
TAD MS 400V / 230V
Menu 3 basic settings and initial operation
Setting the door end positions (menu items 30 and 31)
The upper and lower limit switch must be set directly in succes-
sion.
1.
Select menu 3 "Basic settings" in the control and go to
menu item 30 "Door setting of upper end position", so that
the number 30 blinks on the display.
2.
In order to define the upper end position, keep the but-
ton
pressed until the door is completely open.
ð
If the door moves in the wrong direction, a reversal of
the direction must be implemented. Keep the button
pressed for 5 seconds and then repeat step 2.
3.
When the upper end position has been set, the lower end
position must be adjusted. Exit menu item 30 by pressing
the button
once. The numeric point on the LED display
blinks 5 times and in this way confirms the entry.
4.
Switch to menu item 31 "Door setting of lower end posi-
tion".
5.
In order to define the lower end position, keep the button
pressed until the door is completely closed.
6.
Confirm the entry to complete the setting process.
NOTICE
The door must be spring balanced.
Depending on the driven the door must be spring
balanced.
WARNING
Crush hazard and risk of being struck by the
closing door
Ensure that no closing edge or photoelectric
sensor monitoring is active whilst the end posi-
tions are set.
Fine adjustment of the door end position at the top (menu
item 33) and at the bottom (menu item 34)
1.
Select menu 3 "Basic settings" in the control and go to
menu item 33 "Fine correction upper end position".
ð
The preset value 50 blinks on the LED display.
2.
Values 0 to 99 are provided to you for carrying out a fine
correction. Values of 50 (default setting) to 0 correspond to
0 mm to approx. -80 mm. Values from 50 to 99 correspond
to 0 mm to approx. +80 mm.
3.
Confirm the entry and switch to menu item 34 "Fine correc-
tion lower end position".
4.
Values 0 to 99 are provided to you for carrying out a fine
correction. Values of 50 (default setting) to 0 correspond to
0 mm to approx. -80 mm. Values from 50 to 99 correspond
to 0 mm to approx. +80 mm.
Selection of closing edge J3 / selection of photoelectric
sensor J4 (menu items 35 and 36)
1.
Select menu 3 "Basic settings" in the control and go to
menu item 35 "Closing edge selection".
2.
Select a value corresponding to the desired setting.
3.
Confirm the entry and switch to menu item 36 "Photoelec-
tric sensor selection".
4.
Select a value corresponding to the desired setting.
5.
Confirm the entry to complete the setting process.
Switch-off position of pre-limit switch (menu item 37)
1.
Select menu 3 "Basic settings" in the control and go to
menu item 37 "Correction of pre-limit switch closing edge
safety".
ð
The preset value 25 blinks on the LED display.
2.
Set the switch-off position so that a maximum distance of
50 mm to the ground contact is generated. Values between
0 and 99 are provided to you for this purpose. Values of 25
(default setting) to 0 correspond to 0 mm to approx.
-50 mm. Values from 25 to 99 correspond to 0 mm to ap-
prox. +100 mm.
3.
Confirm the entry to complete the setting process.
NOTICE
Compliance with standard EN 12453
Check the switch-off position of the door after
every setting you have carried out. The switch-off
setting must correspond to a maximum distance
from the ground of 50 mm, otherwise compliance
with the standard EN 12453 is not ensured. This
might result in the loss of certification.
Menu 4 Further door settings
Overrun correction (menu item 42)
The overrun correction compensates for variations of the CLOSE
position, which result from the temperature, running-in of the
gearbox, etc.
Level adjustment (menu item 43)
The level adjustment process compensates for variations of the
CLOSE position, which result from a cable elongation or from a
rise in the floor. The CLOSE end position is adapted by ground
contact of the closing edge safety device. First set the exact
CLOSE position, then select the desired setting for level adjust-
ment in menu 4 under menu item 43. In settings 2, 3 and 4, the
positions programmed in menu 3 are adapted accordingly under
menu items 31, 34 and 37.
Spring fracture detection (menu item 47)
NOTICE
Spring fracture detection function is not a
substitute for a spring fracture safety device
The spring fracture detection function does not
replace the need for a mechanical spring fracture
safety device.
Carry out the following settings for spring fracture detection in
menu item 47 complying with the motor installed:
Motor 9.24/5.24
Input value = U x weight / 20 kg
Motor 9.20
Input value = U x weight / 16 kg
Motor 9.15
Input value = U x weight / 15 kg
U = number of revolutions of the door shaft for complete door
opening
Weight = door leaf weight
Example: Motor 9.24, U = 8 revolutions for door opening, door
leaf weight = 150 kg, with 2 springs each one bears 75 kg.
Switch-off should be at 60 kg.
8 x 60 kg / 20 kg = 24 (input value)
If the value set is exceeded, error F32 is output.
NOTICE
Re-adjusting the door end positions
When the springs have been replaced, the door
end positions must be re-adjusted.
Содержание TAD MS 230V