INSTALLATION
Verify the Installation
1. Turn the Main Disconnect switch to
ON
on the side of the electrical cabinet.
In the electrical cabinet, examine the axis motor drives to determine if the green LEDs are illuminated.
l
If the green LEDs are OFF
, continue to the next step.
l
If the green LEDs are ON
, power off the machine and go to "Troubleshooting" (page 16) > Problem:
The Emergency Stop button doesn't work.
2. Twist out the machine's red Emergency Stop button, which enables movement to the machine axes and the
spindle.
Examine the Reset button to determine if the blue LED is already illuminated.
l
If the blue LED is OFF
, continue to the next step.
l
If the blue LED is ON
, power off the machine and go to "Troubleshooting" (page 16) > Problem: The
Emergency Stop button doesn't work.
3. Press the Reset button.
4. From the PathPilot interface, bring the machine out of reset.
5. On the keyboard, press the
Page Up
key to raise the spindle head off of the wooden block.
6. From the PathPilot interface, reference the Z-, X-, and Y-axis.
The Z-axis motor should operate smoothly and sound like the other two axis motors. If the Z-axis motor
sounds different, go to "Troubleshooting" (page 16).
Page 15
©Tormach® 2022
Specifications subject to change without notice.
tormach.com
TD10801: Installation Guide: 24R Z-Axis Brake Retrofit Kit (0722A)