PROGATE User manual V-2022-09-20
26 |
E N
7.3
System Fault/ Troubles Programming
System Options > System Fault/ Troubles
The System Fault/ Troubles settings let you set the communication options
if the trouble occurs and let you set system voltage loss and restore options.
Figure 37 System Options> System Fault/ Troubles window
1
Trouble
This column lists potential system troubles
10
Enable
The system will detect a marked trouble
11
Restrict ARM
In case of such trouble, the arming activation will be restricted.
2
Battery trouble
Low system voltage. Power supply or backup battery voltage is low, needs to be recharged, or replaced.
3
Clock trouble
The time and date has not been set.
4
BUS trouble
The expansion device is no longer communicating with the module.
5
Tamper trouble
The zone(s) that was tampered
6
Fire loop trouble
The trouble is occurring with your smoke detectors.
7
SIM card trouble
Not available or impossible to read SIM card.
8
Zone ant masking trouble
Do not available in this module
9
GSM network trouble
SIM card is not registered with the GSM network provider
12
Low System Voltage Alarm
The module has detected a low voltage. This means that your system is running on the backup battery
and voltage is dropped below allowed value.
13
System Voltage Restore
The module has detected that the system voltage has been restored.
14
Event Delay
System low voltage trouble event report delay
.
15
Trouble Shutdown
Setting of the allowable number of the same trouble event, where in case of excess of such number the
trouble reporting will be off. The number of such events is counted until the arming mode is changed
(On/Off).
16
Global Tamper Recognition
How the control panel will operate after tamper recognition
18
Tamper Disable
The module will not generate an alarm or trouble.
19
Trouble when disarmed / alarm as per zone when armed
When disarmed: Generates Trouble Only
The module transmits the defined report code.
When armed: Follows Zone Alarm Type
20
Trouble always
Generates Trouble Only (when armed or disarmed)
21
Audible alarm when disarmed / alarm as per zone when armed
When disarmed: Generates Audible Alarm
The module transmits the defined report code and generates an audible alarm.
When armed: Follows Zone Alarm Type
The
module follows the zone’s alarm type.
Figure 38Explanation of every field in "System Fault/Troubles" window
The module can send a system voltage alarm and restore events. It is possible to enable or disable the zone tamper tracking and to set how the module will
operate after tamper recognition.