PROGATE User manual V-2022-09-20
41 |
E N
8.1
The table of installers SMS commands
SMS commands with
correct INST password
can be send from any phone number. Keep INST password in secret!
SMS configuration is allowed only with Latin characters. Unicode is not allowed.
Please note: Symbol
˽ =
Space character
in SMS.
˽
Symbol in examples is used only to make the visual easier to
understand.
Table 6 the table of installers commands
INST000000
˽001˽N#TEL#SMS#DIAL#
e.g.
INST000000˽001˽1#37066666666#11111111#10000000#
Add users telephone numbers to send SMS and to make a call if the event occur:
001= programming user‘s tel. numbers for SMS and DIAL
N = user ID number 1-8
TEL = user‘s telephone number (max 16 digits) without (+) country code, operator‘s code and
user‘s telephone number included. The end symbol #;
SMS = notifications event filter. 1- Send event, 0-
don’t send event. Sequence of the events
1.2.3...n For example: 001000
DIAL = event filter for DIAL. 1-DIAL if the event occur, 0-
don‘t DIAL Sequence of the events
1.2.3...n For example: 101000
#= delimiter
e.g.: INST000000 001 1#37066666666#0001000000#0000011111#
Event filter from left to right 0-disabled;1-enabled:
1.
Alarm/Restore (CID 100 group)
2.
System Open/Close (CID 400 group)
3.
System Troubles(CID 300 group)
4.
Sensor1-Sensor32 Alarm/Restore
5.
Test Events (CID 600 group)
6.
Other Events
7.
Input/Zone1 Alarm/Restore
8.
Input/Zone2 Alarm/Restore
etc…….
INST000000
˽002˽ID
Delete user’s phone number according the
user ID number
. Phone number used for receive
user’s information.
002 = command code (deleting user‘s numbers according the user ID number)
ID = user ID number from 1 to 8
INST000000
˽004˽ID#TEL#OUT#OPT#NAME#
e.g.
INST000000˽004˽1#37066666666#1#10#Jon#
To enter user‘s telephone number for remote control via short call
USER NAME-only Latin characters is allowed inside SMS
004= command code (enter user‘s telephone number for remote control via short call)
ID = user ID number 001-800
TEL = user‘s telephone number (max 16 digits) without (+) comprised of country code, operator‘s
code and user‘s telephone number. the end symbol #;
OUT= output number, that will be controlled, 1-32. 0-Disabled
OPT = 0
– disabled 1 – enabled, Sequence from the left to the right
1.
User Enabled
2.
Enable Arm/Disarm system by call
NAME = User Name
INST000000
˽005˽TEL#
To delete user‘s phone number for remote control, according phone number
005= command code (delete user‘s phone number for remote control, according phone number)
TEL = user‘s phone number (max 16 digits) without (+) comprised of country code, operator‘s code
and user‘s telephone number. User‘s phone number must be the same as in the memory of the
module.
INST000000
˽006˽ID
Delete user‘s all data by index ID
006= command code (Delete user‘s phone number by index )
ID = user‘s index number from 001 to 800.
INST000000
˽007˽P#PER#HH:mm#
e.g.
INST000000
˽007˽1#7#18:30#
Automatic periodical test settings
007= command code (Automatic periodical test)
P= 0-test disabled, 1- test period by 24 hours, 2- period by hours
PER= automatic test sending period from 1 to 99999 days or hours
HH-hours 0-23 ,
mm- minutes 0-59
e.g. INST000000 007 2#1#14:50#
The test will be send every 1 hour
INST000000
˽008˽APN#LOGIN#PSW#
e.g.
INST000000
˽008˽internet###
DATA/GPRS/LTE network settings
008= command code (network settings)
APN=31 symbols
LOGIN=31 symbols
PSW=31 symbols