PROGATE User manual V-2022-09-20
42 |
E N
INST000000
˽009˽ADDR#PORT#PING#KEY#
e.g.
INST000000 009 cloud.topkodas.lt#1000#600#123456#
SERA cloud Service Parameters
009= command code (Remote control of the module over the Internet)
ADDR = the format of IP address xxx.xxx.xxx.xxx (the numbers from 0 to 255 should be separated
by dot or domain text length of up to 47 characters)
PORT= TCP port number .Default:10000
PING= 600 default.
KEY= App Key. App and remote service key. Default:”123456”
Default parameters is in the picture bellow. We recommend do not change these parameters.
INST000000
˽010˽E
Activate/Deactivate SERA Cloud service. APP and remote connection to device.
010= command code (To activate the connection to the remote control server)
E= 1-enabled, 0-disabled
INST000000
˽019˽N#P
To change the operation algorithm of the output
019= command code (To change the operation algorithm of the output)
N = output number from 1 to 32
P = output operation algorithm. 0
– output disabled; 1 – Bell; 2- buzzer; 3- flash led, 4- system state
LED, 5-
LED „system ready“, 6- Automation & access control, 7- AC OK, 8 – Battery OK, 9-
ARM/DISARM 10-alarm indication, 11- Lost Primary channel 12- Lost secondary channel 13- Fire
sensor; 14-RH Sensor trouble; 15- Access Gained
INST000000
˽020˽N
Invert output state
020= command code (outputs inversion)
N = output number from 1 to 32.
INST000000
˽021˽N#ST
Output activation or deactivation
021= command code (Output activation or deactivation)
N = output number 1-32
ST = output mode 0
– OFF, 1- ON
INST000000
˽022˽N#TIME#
Output activation for the time interval
022= command code (Output activation for the time interval)
N = output number 1-32
TIME = 0-999999 Time interval in seconds for the output activation.
INST000000
˽030˽ST
Change security system‘s mode (ARM/DISARM/STAY/SLEEP)
030= command code (Change security system‘s mode)
ST = 0-DISARM, 1-ARM, 2-STAY, 3-SLEEP
INST000000
˽031˽ZN#BYP
Zone bypassing by sms command
031= command code (Zone bypassing)
ZN = zone number from 1 to 32
BYP= 1
– zone bypass 0- zone active.
INST000000
˽063˽S
iButton keys learning/deleting mode
063= command code (iButton keys learning/deleting mode)
S=iButton keys entering/deletion mode.
0-Disable iButton/RFID keys learning mode
1-Enable iButton/RFID keys learning mode
2-iButton/RFID keys deleting mode. To delete these keys from memory, which will be touched to
the reader
INST000000
˽070˽N#VALUE #
e.g.
INST000000
˽070˽1#23.5#
Programming of max sensors value upon reaching, the SMS message with „High Alarm“
text will be sent
070= command
code (max sensors value upon reaching which, the SMS message with „High
Alarm“ text will be sent)
N = sensor number
VALUE= Format 0000.00 High Alarm Value