PROGATE User manual V-2022-09-20
7 |
E N
1.4
General view of the module
Figure 1 General view of the module PROGATE
1.5 Meaning of LEDs and
contacts
Table 3 Meaning of LEDs
Name
Indication variations
Meaning
PWR (green)
Watchdog blinking, on 50ms, and turns off after 1000ms.
The module is functioning.
Off
The module is out of order or no voltage
REG (yellow)
Lights continuously
Modem has been registered to the network
Flashes, remains lit for 50ms, turns off for 300ms
Modem is being registered to the GSM network.
Blinking fast, remains lit for 50ms turns off for 50ms
PIN code of SIM card error. PIN code request should be removed
Off
Modem failed to register to the network.
DATA (red)
Lights continuously
The memory of the module contains unsent reports
Off
Data status is OK. All reports has been send.
RELAY (blue)
ON/OFF
Relay switched ON/OFF
Table 4 Terminal block. Contacts.
Name
Optional functions and Description
AC/DC
DC
10-30V
AC
12-24V
Max
0.2A
NC, C, NO
Relay Output 1A 30 V DC, 0.5A 125 V AC
I/O1-I/O2
Programmable functions
Input with pull up resistor 10K to the VD+
Open drain output 30V/1A
Analog voltage input 0-30V
Max available voltage
30V
IN1/D0 …
IN2/D1
Programmable functions
Input/Zone with pull up resistor 10K to the VD+. Used for gate position or security sensors
Can be configured NC/NO/EOL/EOL+Tamper
Wiegand interface. Inputs D0 and D1 used for wiegand RFID reader, keypad
Max available voltage
30V
COM
Negative supply terminal for keyboard(s), indicators and sensors.
1W
Programmable functions
Digital output (Max 3.3V)
Digital input (Max 3.3V)
Dallas 1-Wire bus. For iButton DS1990A and temperature sensors DS18B20
Aosong 1-Wire bus. Humidity Sensor AM2302, DHT22, AM2305, AM2306
Max available voltage
+3,3V
Max available current
10mA
+5V
Power supply for external temperature, humidity sensors
Max available voltage
+5V
Max available current
100mA
Do not locate SIM card with force, because you may damage SIM card holder