![Topcon ISOBUS Artemis Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/topcon/isobus-artemis/isobus-artemis_operation-manual_1128515008.webp)
ISOBUS ARTEMIS - SEED DRILL CONTROLLER
6
▪
Information totals
The instrument has a special software routine that makes calibration of the metering unit(s) very easy. In the calibration
mode each metering unit is controlled via a ‘priming switch’ to dispense the product. During normal operation the control
system is started and stopped automatically via magnetic sensor(s) as the drill is put into and taken out of work.
2. Multiple Channels / Products
The Artemis has 4 control channels. Each motor / MCM or APM requires a control channel, therefore the number of
channels used depends on the particular drill configuration. Here are some examples.
PRODUCT
CHANNELS
PRODUCT /MOTOR / METERING UNIT CONFIGURATION
SCREEN
DISPLAY
SEED
1
1 PRODUCT
SINGLE MOTOR / METERING
1+2
1
PRODUCT
2
x SINGLE MOTOR / METERING
1
2
2 PRODUCTS
SINGLE MOTOR / METERING (SEED)
SINGLE MOTOR / METERING (FERT A)
SEED
+
FERTILISER
1+2
3+4
2 PRODUCTS
2 x SINGLE MOTOR / METERING (SEED)
2 x SINGLE MOTOR / METERING (FERT)
SEED
+
FERTILISER
1+2
3
2 PRODUCTS
2 x SINGLE MOTOR / METERING (SEED)
SINGLE MOTOR / METERING (FERT A)
1
2
3
3 PRODUCTS
SINGLE MOTOR / METERING (SEED)
SINGLE MOTOR / METERING (FERT)
SINGLE MOTOR / METERING (APPLICATOR)
EED
+
FERTILISER
+
+PELLETS
1+2
3
4
3 PRODUCTS
2 x SINGLE MOTOR / METERING (SEED)
SINGLE MOTOR / METERING (FERT)
SINGLE MOTOR / METERING (APPLICATOR)
2.1 Linked Channels
When a configuration requires multiple hoppers / metering units to dispense a single product, then the control channels
are linked (via the “Factory Setup” menu).
Two, three or four sing
le, adjacent control channels may be linked in this way, and assigned a product type “
Seed
”, “
Fert
A
”, “
Fert B
or “
Pellets
”.