Topcon ISOBUS Artemis Скачать руководство пользователя страница 4

ISOBUS ARTEMIS - SEED DRILL CONTROLLER

 

2

 

Most incidents arising during operation, maintenance and repair are caused by a failure to observe basic safety rules or precautions. Always be alert 

to potential hazards and hazardous situations. Always follow the instructions that accompany a Warning or Caution. The information these provide 
aims to minimize risk of injury and/or damage to property. In particular follow instructions presented as Safety Messages.

 

Safety Messages and Warnings

 

The safety symbol is used with the relevant word : DANGER, WARNING or CAUTION. Messages marked in this way recommend safety precautions 

and practices. LEARN and apply them.

 

DANGER : Indicates an imminently hazardous situation that, if not avoided, could result in DEATH OR VERY SERIOUS INJURY.

 

WARNING : Indicates a potentially hazardous situation that, if not avoided, could result in DEATH OR SERIOUS INJURY.

 

 CAUTION : Indicates a potentially hazardous situation that, if not avoided, could result in MINOR INJURY.

 

Operator Safety

 

Good safety practices not only protect you, but also the people around you. Study this manual as part of your safety program. This safety information 

only relates to Topcon equipment and does not replace other usual safe work practices.

 

 

WARNING: Never operate the machine with any panels or safety guards removed.  Any illustrations or photos in this manual that show 
panels or guards removed are solely for demonstration purposes. If the removal of panels and guards is necessary for calibration or 
maintenance, they MUST be replaced before operation.

 

 

Always check that any suspended vehicle attachments or load arm(s) are lowered to the ground before beginning repair or 
maintenance work on the machine.

 

 

Machine and implement parts can become hot during operation and may be under pressure. Refer to the machine/implement 
manual(s).

 

 

Wear appropriate protective clothing for the task being undertaken.

 

 

Check the Machine is correctly setup/configured and ready for the intended use.

 

 

Be aware of safety instructions for/on the Machine including hazards such as crush zones.

 

 

Prevent the Machine from being accidentally started if working on it e.g. remove the ignition key, place a warning notice in the cab etc.

 

 

Check that the area of Machine operation is clear of people, animals, and obstacles and identify any other possible hazards.

 

 

Keep other persons required to be in the vicinity of the Machine fully aware of Your immediate intentions.

 

If a Topcon Agriculture mobile application is used to augment Your ability to perform tasks that are traditionally performed on the Console directly, 

then in addition to observing the above warnings and all other pre-determined site safety requirements that apply when operating a Machine from 
the Console, You must also observe the following additional requirements when operating the Machine via the Application:

 

 

WARNING: The Application must only be operated by You, the single Console operator wholly responsible for the operation of the 
Machine.

 

 

The Application must only be used when the Machine is not on public roads.

 

 

The Device must be affixed to a rigid mount when used inside the cab while the Machine is moving to avoid a temporary loss of control 
if the Device is dropped or misplaced.

 

 

The Application must only be used outside of the Machine cab when the Machine is stationary.

 

 

When operating the Application outside of the cab of the Machine You must remain within a reasonable distance such that You can 
return to the cab-mounted Console in a timely manner to resume control of the Machine under any of the following circumstances:

 

 

Battery failure on the Device

 

 

Wifi signal is lost or signal strength is too weak for proper operation

 

 

The Device is redirected to another application (e.g. a phone call is received)

 

 

The Device becomes incapacitated (e.g. device is dropped and damaged)

 

 

Any other event that causes the Device to no longer be fit for control of the Application and/or Machine.

 

 

Stand well clear of any moving parts of the Machine (e.g. hydraulic folding booms, spreader spinners, etc.) and areas of product 
application (e.g. Spray Nozzles, NH3 appliers, etc.).

 

 

The Device and Machine must be locked when not in use.

 

Содержание ISOBUS Artemis

Страница 1: ...859 UK ISOBUS Artemis Seed Drill Controller Calibration and Operation Manual ...

Страница 2: ......

Страница 3: ...entation The user documentation and manuals relating the use and operation of the covered Topcon Agriculture product including but not limited to the Console user manuals materials and Application end user license agreement IMPORTANT You must read and follow the Documentation and complete appropriate training before use If You do not operate the System properly it may not correctly apply the Appli...

Страница 4: ... aware of safety instructions for on the Machine including hazards such as crush zones Prevent the Machine from being accidentally started if working on it e g remove the ignition key place a warning notice in the cab etc Check that the area of Machine operation is clear of people animals and obstacles and identify any other possible hazards Keep other persons required to be in the vicinity of the...

Страница 5: ... Seed and fertiliser 10 3 5 2 Pellet Small seed Applicator 10 3 6 Pre start Sequence 11 3 7 Tramlining 12 3 7 1 Advancing the Bout Number 12 3 7 2 Holding the Bout Number 13 3 7 3 Setting the Tramline Rhythm 13 3 8 Forward Speed Display 13 3 8 1 Forward Speed Alarm 13 3 8 2 Simulated Forward Speed 14 3 9 Fan Speed Display 15 3 9 1 Set Fan Speed Alarms 15 3 10 Hopper Level Alarms 15 3 11 Totals 15 ...

Страница 6: ...gle motor as shown in figure 1 Additional CAN modules enable multi channel configurations for combined seed fertiliser pellet application including electro hydraulic control to suit a wide range of drill makes and models 1 1 1 System Components The system will vary depending on the drill make and model but will be some combination of one or more of the following The main electronic components are ...

Страница 7: ...c sensors detect when the Marker arms are lifted lowered Figure 1 Single motor Artemis System Area Cutout Shaft Speed confirmation Sensors Sensor 1 2 Artemis Main Functions The Artemis is designed to allow automatic variable rate control of any drill Also it can control an auxilliary Applicator system e g for Slug Pellets etc You can at any time manually override the predetermined rate as field co...

Страница 8: ...N DISPLAY SEED 1 1 PRODUCT SINGLE MOTOR METERING 1 2 1 PRODUCT 2 x SINGLE MOTOR METERING 1 2 2 PRODUCTS SINGLE MOTOR METERING SEED SINGLE MOTOR METERING FERT A SEED FERTILISER 1 2 3 4 2 PRODUCTS 2 x SINGLE MOTOR METERING SEED 2 x SINGLE MOTOR METERING FERT SEED FERTILISER 1 2 3 2 PRODUCTS 2 x SINGLE MOTOR METERING SEED SINGLE MOTOR METERING FERT A 1 2 3 3 PRODUCTS SINGLE MOTOR METERING SEED SINGLE...

Страница 9: ... UT window NOTE The screens illustrated are as shown on a Topcon UT and in this case the key locations are configurable However the key layout may be different for other other terminals and the key layout may or may not be configurable depending on the terminal Please refer to the OEM manual for the terminal in question 3 1 Artemis Primary Screen Pages NOTE 1 The hydraulic functions screen is spec...

Страница 10: ...Hydraulic functions Info and Setup screens Prestart 3 6 Runs the drill at a simulated speed for a specified time Used when going into work until the target speed is reached e g 8km hr for 5secs Channel On Off 3 3 Turn the channel on off i e start stop the metering motor Tramline Advance 3 7 Increases the tramline bout number by 1 Work Status 3 4 Shows the drill in out of work status and when on a ...

Страница 11: ... 2 linked channels where normally for full width drilling the motors are controlled in tandem indicated by channel icons 1 2 and or 3 4 being linked across the top as shown When half width application is required either left or right metering motor may be switched off by briefly touching the appropriate channel icon s 3 4 Work Status Sensor s detect when the drill is raised out of work or lowered ...

Страница 12: ...the channel that you want to set the rate for Press enter the required rate then touch OK The maximum speed to maintain the application is calculated and displayed Press OK to return to the main screen The system will then automatically maintain this rate rrespective of forward speed within limits To manually override the Rate for a selected channel For the selected channel at any time you can adj...

Страница 13: ...efore moving off The metering motor will run at the calibration speed for the set duration or until the forward speed exceeds the simulation speed when full proportional control then takes over While the pre start duration is active and the forward speed remains below the simulation speed the duration counts down and the Forward Speed display is highlighted yellow Once the simulation speed is reac...

Страница 14: ... 13 14 R 15 16 L 17 18 19 L 20 21 22 3 7 1 Advancing the Bout Number 3 7 2 Holding the Bout Number On starting up the instrument the tramline sequence always starts at 1 If entering work on a bout other than bout 1 of the tramline sequence then you can press the key to select the correct current bout number ...

Страница 15: ... signal input has been lost for whatever reason In this event however you can activate a simulated forward speed so that you are able to continue drilling The drilling rate is metric units only i e km hr The forward speed signal is sourced from either RDS Satspeed 2 converts a GPS NMEA VTG message to a radar compatible speed pulse Radar Sensor You can however press the key to hold the current bout...

Страница 16: ...eed Go to Simulated Speed The factory default simulated forward speed is 10 km hr however this can be changed to match your typical forward speed for drilling Start Stop simulated Speed Go to Simulated Speed Status and check the tickbox to enable NOTE Speed simulation can only be activated when the drill is switched out of work 3 9 Fan Speed Display The Artemis can monitor and display the speed of...

Страница 17: ... Cycle to the Drill Setup screen and touch the tab to view edit the Fan Low Limit and Fan Hi Limit settings UK859 120 PNG Hopper level alarms will alert the operator when the product is running low and or has nearly run out Depending on the drill configuration for each hopper there is either i a single low level sensor ii Both a low level sensor and an upper Pre Level level sensor The additional p...

Страница 18: ... the sensor RED Sensor blocked either at the coulter or at the distribution head The alarm message Seed Sensor xx Row xx Blocked or Fert Sensor xx Row xx Blocked will appear Remove the blockage Note The Sensor No relates to its position on the distribution head The Row No that the sensor is monitoring may not necessarily be the same as the Sensor No ORANGE FLASHING The sensor is detected on the CA...

Страница 19: ...r varying forward speed application e g for Variable Rate Treatment from a plan 5 Product Calibration There are two ways of running the calibration test from the head unit via the relevant priming switch on on the drill 5 1 Running the test from the Cab 1 From the main drilling screen set the target rate for the channel s to be calibrated When a blockage occurs after a pre defined delay time the a...

Страница 20: ...ls are configured the calibration routine must be repeated for each channel including linked channels 4 Select the channel to calibrate then press 5 Press or your preference and enter the weight that you wish to meter out for the bucket test 6 Press The metering unit will then operate based on the simulation speed to dispense the programmed amount of product then stops NOTE At any time you can tou...

Страница 21: ...unit then total both weights 7 Weigh the contents of the container Press or and enter the weight THAT WAS DISPENSED 8 Press The new calibration factor kg rev error and the maximum forward speed that is permissible based on the application rate set for the channel 9 Press to return to the Drill Setup screen UK859 200 PNG 5 2 Running the test using the Priming Switch 1 From the main drilling screen ...

Страница 22: ...t collected weighed and programmed is that from BOTH metering units So at this point press and repeat steps 2 and 3 for the second metering unit and total the dispensed weights 4 Weigh the contents of the container Press or your preference and enter the weight THAT WAS DISPENSED 5 Press The new calibration factor kg rev error and the maximum forward speed that is permissible based on the applicati...

Страница 23: ...ror this time will be marginal 7 Press to accept the error and begin drilling 6 Alarm Codes No Code Screen Reason Check 1 N A High forward speed Forward speed exceeds the maximum calculated and displayed on the RATE screen Target application rate is as required Calibration factor is realistic Adjust metering unit and recalibrate which will increase kg rev factor and therefore increase maximum achi...

Страница 24: ... wiring between 6way connector and module connector on MCM harness 12 M 1 No Code Screen Reason Check 13 M 1 2 Module overload shutdown Motor current requirement exceeded so the module is shutdown and motor operation is inhibited The Motor is stalled Excessive drag on the metering unit requiring motor high current 14 M 1 3 Motor module temperature shutdown Module temperature has exceeded the value...

Страница 25: ...Wiring between sensor and connection box is correct Wiring between connection box and CAN module is correct 18 19 H 1 Tramline module is offline Check module has got power from main battery power cable Check wiring between 4way connector and module connector on HBM harness No Code Screen Reason Check 20 G 1 GPS signal lost Check connections to GPS antenna Check GPS coverage for Area 21 B 1 Bridge ...

Страница 26: ...ed sensor row Row or pipe is actually blocked 25 B M 4 Communication break between blockage sensors Wiring between blockage sensors The correct number of sensors is programmed 26 E H 1 Electro hydraulic module offline Check wiring between 4way superseal and connection to the main loom Issue Ref Date Notes A 14 10 16 1st Draft Derived from UK805200 B 1 3 17 2nd draft re formatted B 23 3 17 3nd draf...

Страница 27: ......

Страница 28: ... 1453 733322 Engineering 44 0 1453 733313 Repair Email info rdstec com Our policy is one of continuous improvement and the information in this document is subject to change without notice Check that the software reference matches that displayed by the instrument Please visit our website for technical support or other product information Replacement user manuals are www rdstec com available on requ...

Отзывы: