![Topcon ISOBUS Artemis Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/topcon/isobus-artemis/isobus-artemis_operation-manual_1128515013.webp)
ISOBUS ARTEMIS - SEED DRILL CONTROLLER
11
UK859-410.PNG
3.6 Pre-start Sequence
UK859-400.PNG
Particularly useful in the case of a front-mounted hopper, the pre-start function helps to avoid an un-seeded area on
entering work. It starts the metering unit at the calibration speed while the drill is still stationary, and ‘primes’ the dri
ll so
that the seed reaches the coulters just as the drill enters work.
User Settings:
Cycle to the ‘Drill Setup’ screen and touch the
tab to view
the ‘Pre
-
start Duration’ and ‘Pre
-
start Mode’.
Pre-start Duration:
The pre-start duration is established by trial and error tests when
the system is first set up. The duration can be set from zero to 9.9
seconds.
UK859-040.PNG
Pre-start Mode:
‘AUTO
’ mode –
the Pre-start function is automatically triggered
when the drill is switched into work.
‘
Man
’ mode
- the pre-start sequence is optional.
As required, simply press the key before moving off.
The metering motor will run at the calibration speed for the set
duration, or until the forward speed exceeds the simulation speed,
when full proportional control then takes over.
While the pre-start duration is active and the forward speed
remains below the simulation speed, the duration counts down
and the Forward Speed display is highlighted yellow.
Once the simulation speed is reached, pre-start is cancelled and
the screen returns to the normal forward speed display.
3.7 Tramlining
The main screen shows the current status of tramlining e.g.
The target no. of bouts can be selected up to 99, with symmetrical, asymmetrical-left or asymmetrical-right rhythm
selectable. A number of special asymmetric rhythms can also be selected to suit the following drill/sprayer width
combinations.
The special tramline sequences (‘L’ –
Left, ‘R’ –
Right) are as follows:
Bout
8-pass
10-pass
10-pass (2)
14-pass
16-pass
18-pass
22-pass
1
2
R
R
L
Rhythm:
Symm
etrical
Asymmetrical
-
left
Asymmetrical
-
right
Output Status (On)
Current Bout
Target N
o of Bouts
UK
859
-
0
50
.PNG
Yellow = Pre
-
start active
Countdown
Содержание ISOBUS Artemis