![Topcon ISOBUS Artemis Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/topcon/isobus-artemis/isobus-artemis_operation-manual_1128515024.webp)
ISOBUS ARTEMIS - SEED DRILL CONTROLLER
22
5
L.3.2
Pre-Level hopper alarm
Channel with low pre
level highlighted
▪
Level is actually low
▪
Sensor is functioning correctly
▪
Wiring between sensor and
connection box is correct
▪
Wiring between connection box and
CAN module is correct
11
M.3.1
Motor speed signal
from motor not being
received
Motor being operated
and pulses received
from shaft confirmation
sensors but no motor
speed signal
▪
Signs of mechanical damage to
encoder or cabling on motor
▪
3way connector between motor and
harness is correct
▪
Wiring between 3way connector and
module connector is correct
MCM or APM is offline’
▪
Check wiring between 6way
connector and module connector on
MCM harness
12
M.1
No.
Code
Screen
Reason
Check?
13
M.1.2
Module overload
shutdown
Motor current
requirement exceeded,
so the module is
shutdown and motor
operation is inhibited
▪
The Motor is stalled.
▪
Excessive drag on the metering unit,
requiring motor high current.
14
M.1.3
Motor module
temperature shutdown
Module temperature
has exceeded the value
programmed
▪
The Motor speed is very low.
▪
Excessive load applied to motor
which for a prolonged time, causing
the module high temperature and
shutdown.
▪
Check metering unit for damage /
obstruction.
▪
Re-calibrate to get motor turning
faster.
15
M.2.L
Motor speed low
Error between actual
motor speed and target
motor speed is greater
than 10%
▪
Target motor speed to high
▪
Erratic forward speed signal
▪
Erratic loading on motor via metering
unit