12-2
12 SETTING ATMOSPHERIC CORRECTION
How to Set the Atmospheric Correction Value Directly
Measure the temperature and air pressure to find atmospheric correction value (PPM) from the chart or
correction formula.
Operating procedure
Operation
Display
1
Press the [F3](S/A) key to set Set Audio Mode
from distance or coordinate measurement mode.
[F3]
2
Press the [F2](PPM) key.
Current setting value is displayed.
[F2]
3
Enter atmospheric correction value. *1)
Mode returns to Set Audio mode.
Enter Data
[F4]
*1) Refer to Section 2.5 “How to Enter Alphanumeric characters”.
Input range: –999.9ppm to +999.9ppm,0.1ppm step
SET AUDIO MODE
PSM:0.0 PPM 0.0
SIGNAL:[
IIIII
]
PRISM PPM T-P –––
PPM SET
PPM
=
0.0 ppm
––– ––– [CLR][ENT]