7-6
7 DATA COLLECTION
Example for setting the direction angle:
The following is to memorize the data of the backsight after setting the backsight point from point
number.
Operating procedure
Operation
Display
1
Press the [F2](BACKSIGHT) key from the data
collect menu 1/2.
The previous data is shown.
[F2]
2
Press the [F4] (BS) key. *1)
[F4]
3
Press the [F1](INPUT) key.
[F1]
4
Enter PT#, press the [F4](ENT) key. *2)
Enter PCODE,R.HT in the same way. *3), 4)
Enter PT#
[F4]
5
Press the [F3](MEAS) key.
[F3]
6
Collimate back sight point.
Select one of the measuring mode and press the
soft key.
EXAMPLE: [F2](Slope Distance) key.
Measuring starts.
Horizontal circle is set to calculated direction
angle.
Measuring result is memorized and the display
returns to the data collect menu 1/2.
Collimate
BS
[F2]
*1) Pressing each time the [F3] key, the input method changes as Coordinate value, Angle, Coordinate
point name alternatively.
*2) Refer to Chapter 2.5 “How to Enter Alphanumeric characters”.
*3) PCODE can be input by inputting a register number linked with PCODE Library.
To show the list of PCODE library, press the [F2](SRCH) key.
*4) Data collect sequence can be set to [MEAS
→
EDIT]. Refer to Section 7.7 “Setting Parameter of Data
If point is not found in internal memory " PT# DOES NOT EXIST" is displayed.
BS#
→
PCODE :
R.HT : 0.000 m
INPUT 0SET MEAS BS
BACKSIGHT
PT#:
INPUT LIST NE/AZ ENT
BACKSIGHT
PT#=
[ALP][SPC][CLR][ENT]
BS#
→
PT-22
PCODE :
R.HT : 0.000 m
INPUT 0SET MEAS BS
BS#
→
PT-22
PCODE :
R.HT : 0.000 m
*VH SD NEZ –––
V : 90°00'00"
HR: 0°00'00"
SD*[n] <<< m
> Measuring...
DATA COLLECT 1/2
F1:OCC.PT# INPUT
F2:BACKSIGHT
F3:FS/SS P
↓
Содержание GREEN LABEL GTS-250 Series
Страница 1: ...ELECTRONIC TOTAL STATION GTS 250 SERIES GTS 252 GTS 255 INSTRUCTION MANUAL 71014 90010...
Страница 2: ......
Страница 138: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Страница 139: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Страница 175: ...APPENDIX 4 APPENDIX...