6-4
6 SPECIAL MODE (Menu Mode)
7
After measuring, the prism position will be
decided.
8
Collimate ground point G.
Collimate G
9
Press the [F4](SET) key.
The position of point G will be decided. *1)
[F4]
10
Collimate target K.
Vertical distance (VD) will be shown. *2)
Collimate K
*1) To return to procedure
5
, press the [F3](HD) key.
To return to procedure
8
, press the [F2](V) key.
*2) To return to PROGRAMS Menu, press the [ESC] key.
REM-2
<STEP-2>
V : 60°45'50"
––– ––– ––– SET
REM-2
<STEP-2>
V : 123°45'50"
––– ––– ––– SET
REM-2
VD: 0.000 m
––– V HD –––
REM-2
VD: 10.456 m
––– V HD –––