7-19
7 DATA COLLECTION
7.5.2 Executing a point to line measurement
Operating procedure
Operation
Display
Conduct data measurement according to the
same procedure as with ordinary FS/SS (ALL can
also be selected). However, when you conduct
observation in the angle mode, PTL data will not
be displayed (only the raw data will be recorded,
upon which the operation will end).
1
Press the [F3](MEAS) key.
[F3]
2
Press the [F2](SD) key.
If the PTL mode is on, then, after the coordinate
data is calculated, the PTL data will be displayed
regardless of the coordinate check setting, etc.
[F2]
3
PTL measurement data will display.
Confirm the data and press [F3](YES) key.
The recorded data are measured data and
coordinate data generated at the same time as a
PTL data.
[F3]
In the PTL measurement mode, NEZ Auto Calculation wil be turned on compulsorily and the
coordinate data will be stored into a coordinate file.
PT#PTL
→
PT-01
PCODE :TOPCON
R.HT : 1.500 m
INPUT SRCH MEAS ALL
PT#PTL
→
PT-01
PCODE :TOPCON
R.HT : 1.500 m
VH *SD NEZ
V : 90°10'20"
HR: 120°30'40"
SD* < m
> Measuring...
L: 44.789 m
O: 33.456 m
E: 2.321 m
>REC? [YES][NO]
PT#PTL
→
PT-02
PCODE :TOPCON
R.HT : 1.500 m
INPUT SRCH MEAS ALL