16-2
16 SELECTING MODE
EDM OFF
TIME
0-99
The time when EDM is cut off from distance
measurement is completed can be changed. This
function is effective for shortening the first time
measuring time when distance
measurement is started from distance
measurement completing state. (Default: 3minutes)
0: After completing distance measurement,
EDM is cut off immediately.
1-98: EDM is cut off after 1~98 minutes.
99: EDM is always switched ON.
FINE
READING
0.2/1mm
Select 1mm or 0.2mm for the minimum reading
unit in the distance mode (FINE mode).
OFFSET V
ANG
FREE/HOLD
Select Vertical angle setting in the Angle Offset
measurement mode.
FREE: Vertical angle varies by the angle of the
telescope.
HOLD: Vertical angle is fixed even if the angle of
the telescope changes.
3:
OTHERS
SET
H-ANGLE
BUZZER
ON/OFF
Specify whether the buzzer sounds or not for every
horizontal angle 90°.
S/A BUZZER
ON/OFF
Specify whether the buzzer sounds or not in the set
audio mode.
W-
CORRECTION
OFF/K=0.14/
K=0.20
Set correction for refraction and earth curvature,
coefficient of refraction as; K=0.14, K=0.20 or no
correction.
NEZ
MEMORY
ON/OFF
It is possible to retain the coordinate of instrument
point, the instrument height and prism height after
power off.
REC TYPE
REC-A/REC-B
Select REC-A or REC-B for data output.
REC-A: The measurement is made again and this
new data is output.
REC-B: The data being displayed is output.
CR, LF
ON/OFF
It is possible to output the data with carriage return
and line feed.
NEZ REC
FORM
STANDARD/
STANDARD
(12dig)/
with RAW
with RAW (12dig)
Select the format of the record coordinates data
STANDARD:
11 digits standard data
STASNDARD (12dig): 12 digits standard data
with RAW:
11digits standard data with
raw data
with RAW (12dig):
12digits standard data with
raw data
MANUAL
NEZ REC
ON/OFF
In the layout mode or data collect mode, it is
possible to record coordinates entered directly from
the keyboard.
LANGUAGE
*1)
ENGLISH/
OTHER *1)
Select the displaying language.
ACK MODE
STANDARD/
OMITTED
Set the procedure of the communication with
external device.
STANDARD: Normal procedure
OMITTED:
Even though the [ACK] is omitted
from the external device, the data is
not sent again.
GRID
FACTOR
USE G.F./
DON’T USE
Select using GRID FACTOR in calculation of
measurement data.