5 PROGRAM MODES
5-22
5
Collimate the left side of the column (P2) and
press the [F6](SET) key.
After the measurement, angle measuring
display of the right side (P3) will be shown.
Collimate
P2
[F6]
6
Collimate the right side of the column (P3)
and press the [F6](SET) key.
After the measurement, the distance between
the instrument and center of the column (P0)
will be calculated and displayed.
Collimate
P3
[F6]
7
To show the slope distance of point P0, press
the [F2](SD) key.
[F2]
8
To show the coordinates, press the [F3](NEZ)
key. *1)
[F3]
*1) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 4.
COLUMN OFFSET
Right
HR : 95
°
3 0'40"
SET
COLUMN OFFSET
HR: 90
°
30' 40"
HD: 10.321 m
VD: 0.886 m
NEXT SD NEZ REC
COLUMN OFFSET
V : 85
°
30'30"
HR: 90
°
3 0'40"
SD: 10.999 m
NEXT HD NEZ REC
COLUMN OFFSET
N : 17.321 m
E : 10.962 m
Z : 0.886 m
NEXT SD HD REC