20 SPECIFICATIONS
20-2
Measurement accuracy
Non-prism mode (Diffusing Surface)
3 to 25m (9.8 to 82ft):
± (10mm) m.s.e.
25m or more (82ft or more):
± (5mm +2ppm •D) m.s.e.
D: Measuring distance (mm)
Prism mode
Fine measurement mode:
±(3mm +2ppm •D) m.s.e.
Course measurement mode:
±(10mm +2ppm •D) m.s.e.
D: Measuring distance (mm)
Least Count in Measurement
Fine measurement mode:
1mm (0.005ft.) / 0.2mm (0.001ft)
Coarse (1mm) measurement mode:
1mm (0.005ft.)
Coarse (10mm) measurement mode:
10mm (0.02ft.)
Measurement Display:
10digit : max. display ±999999.9999m
Measurement Time
Fine measurement mode:
1mm : 1.2 sec. (Initial 3 sec.)
:
0.2mm: 3 sec. (Initial 4 sec.)
Coarse (1mm) measurement mode:
0.5sec. (Initial 2.5sec.)
Coarse (10mm) measurement mode:
0.3sec. (Initial 2.5sec.)
(The initial time will be different by a condition.)
Atmospheric Correction Range:
–999.9ppm to +999.9ppm , in 0.1ppm increments
Prism Constant Correction Range:
–99.9 mm to +99.9 mm , in 0.1 mm increments
Coefficient Factor:
Meter / Feet
International feet 1meter = 3.2808398501 ft.
US SURVEY feet 1meter = 3.2808333333 ft.
Ambient Temperature Range:
–20°C to +50°C (–4°F to +122°F)
Distance measurement
Measurement range
Non-prism mode (Target: White wall)
Prism mode
Condition 1:Sight haze with visibility about 20km (12.5miles) moderate sunlight
with light heat shimmer.
Atmospheric conditions
In low light condition and without
sun glare on target
3 to 120 m (9.8 to 394 ft)
Prism
Atmospheric conditions
Condition 1
Mini prism
2 to1,500m (6.6 to 4,920ft)
Prism type 2, with 1 prism
2 to 7,000m (6.6 to 22,900ft)
Содержание GPT-8000 Series