38
Speed trial
Line, JOG
Row torque limit
•
Set the torque limit value in the speed trial run and JOG operation
mode.
•
Independent of the direction of rotation, it is effective in both direc
-
tions.
•
The set value is a percentage of the rated torque, for example, set to
the rated torque 1 time, the setting value is 100.
•
Internal and external torque limits are still valid.
39
Analog torque
Instruction zero offset
Pay
The amount of zero offset compensation for the analog torque input.
40
Acceleration time
Number
•
The set value is the acceleration time of the motor from 0 to 1000 r/
min.
•
The acceleration and deceleration characteristics are linear.
•
Only for speed control mode, position control mode is invalid.
•
If the drive is used in combination with an external position loop, this
parameter should be set to 0.
41
Acceleration time
number
•
The set value is the acceleration time of the motor from 0 to 1000 r/
min.
•
The acceleration and deceleration characteristics are linear.
•
Only for speed control mode, position control mode is invalid.
•
If the drive is used in combination with an external position loop, this
parameter should be set to 0.
42
S type acceleration and
deceleration
Time constant
•
Set the S-type acceleration/deceleration curve part of the time to
make the motor start and stop smoothly.
43
Analog speed
Command input in
-
crease
beneficial
Set the ratio between the analog speed input voltage and the actual running
speed of the motor
relationship.
44
Analog speed
Command direction
anti-
•
Reverse the polarity of the analog speed input.
•
When set to 0, the analog speed command is positive and the speed
direction is CCW;
•
When set to 1, the analog speed command is positive and the speed
direction is CW.
0~1
45
Analog speed
Instruction zero offset
Pay
The amount of zero offset compensation for the analog speed input.
46
Analog speed
Instruction filter
•
Low-pass filter for analog speed input.
•
The larger the setting, the faster the response to the speed input
analog, the signal noise
•
The louder the influence; the smaller the setting, the slower the
response, the signal noise
•
The smaller the ringing.