7
Chapter 3 Interface
3.1 2A/3A driver power terminal TB
Table 3.1 Power terminal TB
Termin
al
number
Terminal
mark
Signal name
Featu
res
1
PE
System ground
Ground terminal
2
R
Main circuit
power input
three-phase
ac220v
Main circuit power input terminal
AC220V 50Hz
Note: Do not connect to the motor output
terminals u, v, w.
3
S
4
T
5
U
Servo motor power
output
Output to the servo motor power supply,
It must be connected to the motor u, v, w
terminals one-to-one.
6
V
7
W
8
PE
Ground
Ground terminal, connected to the outer casing of
the motor
9
r
Control power input
Single phase ac220v
Control loop power input terminal
AC 220V 50Hz
10
t