Electrical Safety 

1. 

Grounded  tools  must  be  plugged 
into an outlet properly installed and 
grounded  in  accordance  with  all 
codes  and  ordinances.  Never 
remove  the  grounding  prong  or 
modify the plug in any way. Do not 
use  any  adapter  plugs.  Check  with 
a  qualified  electrician  if  you  are  in 
doubt whether the outlet is properly 
grounded.

 

If 

the 

tool 

should 

electrically malfunction or break down, 
grounding  provides  a  low  resistance 
path to carry electricity away from the 
user. 

2. 

Double 

insulated 

tools 

are 

equipped with a polarized plug (one 
blade is wider than the other). This 
plug will fit in a polarized outlet only 
one  way.  If  the  plug  does  not  fit 
fully in the outlet, reverse the plug. 
If  it  still  does  not  fit,  contact  a 
qualified  electrician  to  install  a 
polarized outlet. Do not change the 
plug  in  any  way. 

Double  insulation 

eliminates the need for the three wire 
grounded  power  cord  and  grounded 
power supply system. 

3. 

Avoid  body  contact  with  grounded 
surfaces  such  as  pipes,  radiators, 
ranges,  and  refrigerators.

  There  is 

an  increased  risk  of  electric  shock  if 
your body is grounded. 

4. 

Do  not  expose  power  tools  to  rain 
or  wet  conditions.

  Water  entering  a 

power  tool  will  increase  the  risk  of 
electric shock. 

5. 

Do  not  abuse  the  Power  Cord. 
Never  use  the  Power  Cord  to  carry 
the  tool  or  pull  the  Plug  from  an 
outlet.  Keep  the  Power  Cord  away 
from  heat,  oil,  sharp  edges,  or 
moving  parts.  Replace  damaged 
Power Cords immediately. 

Damaged 

Power  Cords  increase  the  risk  of 
electric shock. 

6. 

When  operating  a  power  tool 
outside,  sue  an  outdoor  extension 
cord  marker  “W-A”  or  “W”. 

These 

extension  cords  are  rated  for  outdoor 
use,  and  reduce  the  risk  of  electric 
shock. 

 
 
 

 

Personal Safety 

1. 

Stay  alert.  Watch  what  you  are 
doing,  and  use  common  sense 
when  operating  a  power  tool.  Do 
not  use  a  power  tool  while  tired  or 
under  the  influence  of  drugs, 
alcohol, or medication.

 A moment of 

inattention while operating power tools 
may result in serious personal injury. 

2. 

Dress  properly.  Do  not  wear  loose 
clothing  or  jewelry.  Contain  long 
hair.  Keep  your  hair,  clothing,  and 
gloves  away  from  moving  parts. 

Loose  clothes,  jewelry,  or  long  hair 
can be caught in moving parts. 

3. 

Avoid  accidental  staring.  Be  sure 
the  Power  Switch  is  off  before 
plugging in.

 Carrying power tools with 

your  finger  on  the  Power  Switch,  or 
plugging in power tools with the Power 
Switch on, invites accidents. 

4. 

Remove 

adjusting 

keys 

or 

wrenches before turning the power 
tool on

. A wrench or a key that is left 

attached to a rotating part of the power 
tool may result in personal injury. 

5. 

Do  not  overreach.  Keep  proper 
footing  and  balance  at  all  times. 

Proper  footing  and  balance  enables 
better  control  of  the  power  tool  in 
unexpected situations. 

6. 

Use safety equipment. Always wear 

Содержание 597077

Страница 1: ...1 27 1 ...

Страница 2: ... the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE is used to address practices not related to personal injury SAFETY WARNINGS AND PRECAUTIONS WARNING When using tool basic safety precautions should always be followed to reduce the risk of personal injury and damage to equipment Read all instructions before using thi...

Страница 3: ... Power Cord to carry the tool or pull the Plug from an outlet Keep the Power Cord away from heat oil sharp edges or moving parts Replace damaged Power Cords immediately Damaged Power Cords increase the risk of electric shock 6 When operating a power tool outside sue an outdoor extension cord marker W A or W These extension cords are rated for outdoor use and reduce the risk of electric shock Perso...

Страница 4: ... tools are less likely to bind and are easier to control Do not use a damaged tool Tag damaged tools Do not use until repaired 7 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tool s operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools 8 Use only accessories that are recommende...

Страница 5: ... or any flammable substances Wear dry insulating gloves and protective clothing d Wear an approved head covering to protect the head and neck Use aprons cape sleeves shoulder covers and bibs designed and approved for welding and cutting procedures e When welding cutting overhead or in confined spaces wear flame resistant ear plugs or ear muffs to keep sparks out of ears 8 Prevent accidental fires ...

Страница 6: ... sampling to determine the need for corrective measures Use mechanical ventilation to improve air quality If engineering controls are not feasible use an approved respirator Work in a confined area only if it is well ventilated or while wearing an air supplied respirator Follow OSHA guidelines for Permissible Exposure Limits PEL s for various fumes and gases Follow the American Conference of Gover...

Страница 7: ...ike a cylinder Do not use cylinders that have been dented Cylinder caps should be used when moving or storing cylinders Empty cylinders should be kept in specified areas and clearly marked empty 13 Never use oil or grease on any inlet connector outlet connector or cylinder valves 14 Use only supplied Torch on this Inverter Air Plasma Cutter Using components from other systems may cause personal in...

Страница 8: ...rrent A 10 200 10 200 No load voltage V 64 64 AC Pulse frequency Hz 0 2 20 DC Pulse frequency Hz 0 2 500 0 2 500 Pulse and empty ration 1 99 1 99 AC frequency Hz 20 150 AC clean width 20 20 AC clean scope 15 40 Current up down slope time S 0 15 0 15 Gas pre flow time S 0 1S 0 1S Gas post flow time S 0 99 95 0 99 95 Rated duty cycle 35 200 60 152 100 118 35 200 60 152 100 118 Efficiency under rated...

Страница 9: ...e a sturdy work table that is open below the area you are cutting Molten slag will be blown through the work metal and must be able to fall away freely 2 Your work table must allow the work metal to be firmly clamped to prevent it accidentally falling or moving 3 The floor and surrounding area of your work site must not be flammable A clean cement floor is recommended The cutting process will ejec...

Страница 10: ...ling Panel Instruction DC TIG 200 The welding machine control panels as above shows are used for functions selection and parameter enactment It includes figure display window adjustment knob and LBD indicator light NOTE THE LEB INDICATOR LIGHT ILLUMINATION SHOW THE STATE YOU ARE Gas bottle trailer for holding it 2 1 3 5 4 ...

Страница 11: ...to right in order the indicator on position stands for current estate AUTO means automatic welding and nothing can be adjusted except current MMA means MMA welding PULSE TIG means TIG welding with pulse function TIG means the common TIG welding 15 2 4T 2T selection button Selecting 4T 2T procedure functions TIG welding divides into 2T action non self lock and 4T action self lock both AC PULSE TIG ...

Страница 12: ...indicator on adjust ADJUSTMENT PAR 6 button to set GAS PRE FLOW GAS POST FLOW time 3 0s 99 9 0s When the STARTING AMP indicator on adjust ADJUSTMENT PAR 6 button to set STARTING AMP FINAL AMP Current 315 270 250 15A and using the same way to adjust beforehand for the followings CURRENT UP SLOPE CURRENT DOWN SLOPE time 15 0S TIG 315 270 250 15A BASE AMP PEAK AMP current 315 270 250 15A PULSE WIDTH ...

Страница 13: ...e constant current output estate 5 PEAK AMP the peak value current when pulse outputting 6 PULSE WIDTN Time proportion of peak value current when pulse outputting which controls the welding line deep and realize entire position welding and sheet welding 7 PULSE FREQ Working frequency when pulse outputting 8 AC FREQ Output frequency of AC working 9 CLEAN WIDTN the time proportion of minus direction...

Страница 14: ...in after welding is finished at this time the welding current begin down to end ARC current and retain it The welding machine stops outputting current after releasing torch switch for the second time 18 4 parameter adjustment towards the left You can choose any procedure function among GAS PRE FLOW GAS POST FLOW STARTING AMP FINAL AMP CURRENT UP SLOPE CURRENT DOWN SLOPE TIG AC PULSE FREQUENCY BASE...

Страница 15: ...AC CLEAN WIDTH 40 40 CLEAN SCOPE 30 15 Long time pressing this button can realize speediness adjustment This button just can adjust these parameters from high to low Also it can used for adjusting welding current from low to high when the STICK is used This welding machine can auto save data when it is power off which could be used directly of next time NOTE Protection Code May showed on the digit...

Страница 16: ...efore plugging the MMA welding plug As the following picture show AC DC TIG 200 MMA Welding As for this kind welder MMA welding is not recommended OPERATION Note Before beginning please read and understand all the safety precautions staring on page 1 and especially the section Specific Safety Rules starting on page 3 1 Connect the TIG torch control cable plug and gas outlet hose as shown on page 9...

Страница 17: ...nto the torch d Screw the Collect Housing and Ceramic Nozzle back onto the Torch 4 Connect a hose and coupling from the gas regulator on an Argon gas tank none included to the Argon Gas Inlet on the back of the unit Follow the gas cylinder manufacturer s instructions for set up and use 5 Verify that the Power Switch is in the off position then plug the 230V line cord plug into an appropriate 230V ...

Страница 18: ...de 804 will be showed on the digital display at the same time the welder will turn off until it cools down It will automatically reset When finished welding a Release the Torch handle trigger and lift the Torch handle from the work piece b Press the Power Switch to the Off O position c Set the Torch handle down on the metal workbench d Turn the air supply off Unplug the line cord from the electric...

Страница 19: ...4 7 10 200 320 3 2 10 15 320 400 4 0 12 20 400 640 4 8 15 25 2 STAINLESS STEEL SUS304 WELDING PARAMETER Steel thickness Tungsten diameter Wire diameter Welding current Argon flux Clearance size Clearance form mm mm mm A L min mm 0 6 1 0 1 6 0 1 0 15 30 4 5 1 a b 1 0 1 0 1 6 0 1 6 25 30 4 7 1 a b 1 5 1 0 1 6 0 1 6 50 70 6 9 1 b 2 5 1 6 2 4 1 6 2 4 65 95 6 9 1 b 3 0 1 6 2 4 1 6 2 4 90 120 7 10 1 2 b...

Страница 20: ...NANCE WARNING Make sure the Power Switch of the Plasma Cutter is in its OFF position and that the tool is unplugged from the electrical outlet before performing any inspection maintenance or cleaning procedures 1 Before each use inspect the general condition of the Welder Check for loose cable connections misalignment or binding of the fan cracked or broken parts damaged electrical wiring and any ...

Страница 21: ...home user is strongly advised not to remove the tool covers and not to attempt any electronic repairs Any repairs must be completed by a qualified technician Opening the tool will void any warranties and may result in damage to equipment or possible personal injury Don t do it 9 On a daily basis check for any of the following problems If any are found take the tool to a qualified repair technician...

Страница 22: ...22 27 22 PART LIST AC DC TIG200 ...

Страница 23: ...cket for pressure board WSE 200IGBT 25 PCS 1 14 205012981 Bracket for main transformer WSE 200IGBT 825 PCS 1 15 204005024 reactance EL10120080 WSE 200IGBT PCS 1 16 304014028 fan guard φ150 G17050HA2BL EACO 09 PCS 1 17 202000695 inverter board for WSE 200 FHP06640604 1 IKW50N60TFHP06640604 3 06640604 2 PCS 1 18 205005044 Bracket for radiator IGBTEACO 11 075785706698 PCS 1 19 205012853 pedestal WSE ...

Страница 24: ...V PCS 1 25 26 27 202000696 RC absorbent board EP10120058 PCS 1 32 33 303021052 temperature controller TH B2D 65 5 45 15 70mm PCS 2 PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MAUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT H...

Страница 25: ...d WSM 250IGBT PCS 1 4 30300105002 metallic resistance 50W 10R PCS 1 5 205012180 Bracket for pressure board WSE 250 315 350 400I PCS 1 6 202000364 high pressure board FHP06620603 5 FHP06620603 4 PCS 1 9 202000654 high frequency HF absorption PBC for cutting machine EP10080040 PCS 1 10 30300103015 SQP RX27 40W 390R PCS 1 11 202000252 Inspection current board for NB 200 250 FHP06260607 NB 200 250 400...

Страница 26: ...for IGBT NB 160 EP10080036 PCS 1 26 202000538 Drive board for DSP IGBT EP09100005 1 EP09100005 NB 350 500 LGK 60 80IGBT PCS 1 27 205005041 Temperature contro lled presser MAX ARC 160MINI PCS 1 28 303021051 temperature controller TH B2D 60 5 0mm PCS 1 29 303004168 fast recovery diode DH2F160N4SE PCS 1 30 303023060 fan G17050HA2BL 230V PCS 1 31 304014028 fan guard φ150 G17050HA2BL EACO 09 PCS 1 33 2...

Страница 27: ...amp is attached is clean exposed metal free of dirt paint and oil No weld output high temperature light on 1 Welder overheated 2 Duty cycle or amps too high 3 Airflow is blocked 1 Allow unit to cool with the fan on 2 Reduce duty cycle or amps 3 Clean vents and fan out with compressed air Erratic or improper arc or welding output 1 Bad weld connections 2 Polarity incorrect 3 Work piece painted or d...