14
/
27
14
before finishing welding
14. GAS POST-FLOW——Gas extending
time after welding is finished. It can
protect the welding line and the
15.
1#: MODE Selector button
: Press
this button some times as needed
to
choose the
four functions above : MMA, Pulse TIG,
TIG, AUTO( from left to right in
order).the indicator on position stands
for current estate. AUTO means
automatic welding and nothing can be
adjusted except current; MMA means:
MMA welding; PULSE TIG means TIG
welding with pulse function; TIG
means the common TIG welding.
16.
2#: “AC/DC” selection button
:
selecting “AC/DC” functions, TIG
welding divides into AC welding and
DC welding
,
the indicator on position
stands for current status.
17.
3#: “4T/2T” selection button
:
Selecting “4T/2T” procedure functions,
TIG welding divides into “2T” action
(
non-self lock
)
and “4T” action
(
self
lock
),
both AC(PULSE TIG/TIG) and
DC(PULSE TIG/TIG) can realize
“4T/2T” selection. “2T” means to start
welding when press the torch switch
and stop welding when the torch
switch is released.
“4T” action style means output ARC
striking current when press torch
switch for the first time, current up to
standard welding current while
releasing the torch switch. Press the
torch switch again after welding is
finished, at this time the welding
current begin down to end-ARC
current and retain it. The welding
machine stops outputting current
after releasing torch switch for the
second time.
18. 4#: parameter adjustment(towards
the left)
:
You can choose any procedure
function
among
“GAS
PRE-FLOW/GAS
POST-FLOW,
STARTING
AMP./FINAL
AMP.
,CURRENT
UP
SLOPE/CURRENT
DOWN
SLOPE,TIG,
AC/PULSE
FREQUENCY, BASE AMP./PEAK
AMP.,CLEAN
WIDTH/CLEAN
SCOPE /PULSE WIDTH” by press
this button . The illumination indicator
stands for the current status you are
choosing.
The
indicator
will
illuminate
from the right to left in
order while you press
. Also when it is
MMA welding, the button can adjust
(just decrease) ARC force.
19.
5#:parameter adjustment(towards
the right)
:
You can choose any procedure
function
among
“GAS
PRE-FLOW/GAS
POST-FLOW,
STARTING
AMP./FINAL
AMP.
,CURRENT
UP
SLOPE/CURRENT
DOWN
SLOPE,TIG,
AC/PULSE
FREQUENCY, BASE AMP./PEAK
AMP.,CLEAN
WIDTH/CLEAN
SCOPE /PULSE WIDTH” by press
this button . The illumination indicator
stands for the current status you are
choosing.
The
indicator
will
illuminate
from the left to right in
order while you press.
Also when it is
MMA welding, the button can adjust
(just increase) ARC force.
20.
6#: “Parameter Adjustment Knob”:
After choosing the procedure function
(refer to item 18 and 19), the current
status are set, then you can turn this
knob to adjust its parameter value. For
Содержание 597077
Страница 1: ...1 27 1 ...
Страница 22: ...22 27 22 PART LIST AC DC TIG200 ...