21
13. About Memory
Programmed data parameters are stored in the non-volatile IC memory.
With the stored data, capacitors (C1 and C2) are preset accordingly, next time the tuner is operated.
Operating Status Memory (RESUME Memory)
Memory and Status is stored when the tuner powered is off, and recalled
again when power is turned back on.
They are, Band (Freq.), Tuning Position (C1, C2), Antenna Port, and
, Interface Setting.
* If the transceiver setting has been changed after the power is turned on,
the tuner settings will be changed accordingly.
Setting Status Memory
Various parameters which are selected for each band are memorized for that band
respectively
Memory Contents
Antenna (ANT1-TRU3) selected for each band.
Default
Each band defaults to ANT1 port
Tuning Memory
Recall
Recalled every time band is changed.
Note
Since only one antenna is memorized per band, it is impossible to select more than one
Ant port per band.
A function to memorize the last tuning positions (C1, C2).
Memory Contents
C1, C2 positions for each frequency and Antenna 1 thru 3.
Frequency divisions.
CI-V, KEN, FRQ modes: 93 divisions x3
NON,YAE, THP modes: 22divisions x3
Default
50 ohm load tuning position (c1,C2) for ANT1 thru ANT3. (See page 26)
Recall
Recalled as frequency and or antenna is changed.
Note
When the transceiver is changed from ICOM to YAESU, YAESU memory data is recalled
rather than ICOM’s memory.