8
4. Components
(1)
Interchangeable head
The drawing above shows attached QH interchangeable head. Tohnichi head SH, RH, RQH,
DH, HH and FH are also available. NOTE: PH head can't be used
(2)
Wireless LAN module
There are wireless LAN module and antenna inside
(3)
Liquid crystal display (LCD)
It shows counter number, Hi/ Lo torque values, battery life indicator, unit of measure and clock
(4)
7 segments LED display
It shows torque value
(5)
Tightening completion, judgment LED
Blue LED turns on for tightening completion OK and red LED turns on for NG
(6)
: Power button
Switch to poser on and off. When power is on, does zero check on torque measurement
Press and hold it for 2 seconds to turn off wireless LAN module power
(7)
: Upper arrow key
Sends a counter one by one or continuously to read out the measured
Press and hold to fast-forward
(8)
:Down arrow key
Sends a counter one by one or continuously to read out the measured
Press and hold to fast-forward
(9)
Terminal cover
This cover protects each terminal from dust and debris
(10)
:
Mode key
When counter 000: Press and hold for 2 seconds to move to setting mode
(11)
: Memory key
Saves and transfers the displayed data to external device
(1
)
(2)
(3) (4)
(5)
(6) (7) (8)
(9) (10) (11) (12)
(13)
(14)
(16) (17)
(15)