17
7.3.
High/ Low limit values display mode with judgment
Shows High/ Low limit values on left display. When press
key or Auto reset It makes
judgment in the range or not after measurement, then outputs data to the server
i.
Set measurement mode to “MODE-M” (Default)
ii.
Set display mode to “TORQUE” and High/ Low limit values
NOTE: if you set High/ Low limits to "0" tool does not judge.
On this instruction manual, set to 45 Nm for High limit, to 30 Nm for low limit for example.
iii.
Make sure the LCD left side display shows High/ Low limit values then measure
NOTE: Display can captures from about 7.5% of torque capability
iv.
When press
key after measurement, tool judges the result. If there is Auto memory/
reset setting the judgment will be performed automatically.
[When judgment is OK]
Shows the solid blue LED for about 0.5 seconds and stores the data. If there is wireless LAN
connection on the tool, it outputs data.
[When judgment is NG]
The red LED turns on and buzzer sounds continuously. Press
key to save and output
the data, or press
key to clear.
If there is "NGAUTO" output setting the data will be output automatically even if get judgment
result is NG. If there is wireless LAN connection on the tool, it outputs data.
v.
Peak torque on the display will be reset and ready to next measurement
NOTE: The tool does not store the data under “TORQUE” mode