20
v.
Once reaches on low limit torque value the tool gives beep continuous and blue LED.
[When judgment is OK]
vi.
When press
key after measurement, tool stores the peak torque and timestamp. If
there is wireless LAN connection on the tool, it outputs them.
NOTE: The time of timestamp is at the
key pressed. If there is Auto memory/ reset
setting the data are stored/ output automatically.
[When judgment is NG]
vii.
Peak torque on the display will be reset and ready to next measurement
NOTE: The tool does not store the data under “TORQUE” mode