16
7.2.
Counter display mode with judgment
Captures the peak torque and makes judgment due to your setting tolerance. Then stores and
outputs the data to server
i.
Set measurement mode to “MODE-M” (Default)
ii.
Set display mode to “MEMCNT” and High/ Low limit values
NOTE: if you set Hi/ Lo limits to "0" tool does not judge.
On this instruction manual, set to 55 Nm for High limit, to 45 Nm for low limit for example.
iii.
Make sure the LCD left side display shows counter between “001” to “999” then measure
NOTE: Display can captures from about 7.5% of torque capability
iv.
When press
key after measurement, tool judges the result. If there is Auto memory/
reset setting the judgment will be performed automatically.
[When judgment is OK]
Shows the solid blue LED for about 0.5 seconds and stores the data. If there is wireless LAN
connection on the tool, it outputs data.
[When judgment is NG]
The red LED turns on and buzzer sounds continuously. Press
key to save and output
the data, or press
key to clear.
If there is "NGAUTO" output setting the data will be output automatically even if get judgment
result is NG. If there is wireless LAN connection on the tool, it outputs data.
v.
Peak torque on the display will be reset and goes to next counter
NOTE: if there is a measured data on the counter number display shows it