5. Explanation of each mode
CEM3-G-WF has two modes that are Measurement mode and Display mode
5.1. Measurement mode
(Default: MODE-T)
Inspection mode (MODE-M)
MODE-M is ideal for re-tightening and breakaway inspections. The tool makes judgement the
measured torque result if there are set the High/ Low limit torque values.
Tightening mode (MODE-T)
MODE-T is ideal for tightening process. When you set the High/ Low limit torque values the tool
gives beep intermittent and blue LED blinking if the torque value reaches about 80% of lower limit
torque. Once reaches on lower limit torque value the tool gives beep continuous and solid blue LED
to tell tightening completion. The Hi/ Lo torque values can be set through wireless LAN.
5.2. Display mode
(Default: MEMCNT)
RUN mode (The counter is “000”)
The display shows the torque value being applied at the moment and returns to zero when torque is
released.
MEMCNT (Memory counter display mode)
The left display shows memory counter number and right display shows torque value. The maximum
torque will be captured and the right display holds it. When you save the data, it is tied with counter
number and stored with time stamp on the tool.
TORQUE (High/ Low limit torque display mode)
The left display shows lower limit torque on upper left corner and upper limit torque on middle of
display. The maximum torque will be captured and the right display holds it.