3-24
N-CC1000/CC1110/VT1010 INSTRUCTION MANUAL (Applications)
CHAPTER 3. Performing Settings with Internet Explorer
3.8. ALARM SETTING SCREEN
Set the camera’s behavior when an alarm is triggered.
Alarm Setting Screen
3.8.1. Alarm Trigger
Video Loss
Sets whether to trigger an alarm when video loss occurs or camera operation stops. Alarm is triggered if the
option is set to On.
Alarm Input
Monitors the remote sensor connected to the Alarm Input terminal. Alarm is triggered when the sensor
operates.
On : Select to trigger an alarm by means of external sensors.
Off : Select to deactivate the alarm.