Autopilot Section
Roll Axis Setup
Roll Axis Setup
This submenu provides settings of the AP performance during a roll of the aircraft.
•
Menu Roll Axis Setup
•
Control Sensitivity
•
Mode-Turn Rate
•
Mode-Bank Angle
•
Max. Bank Angle
•
Turn Rate Target
Control Sensitivity
This parameter specifies how fast the AP reacts to deviations between target heading and actual heading. If the parameter is adjusted too high, the
aircraft will be itchy. Fast, hardline adjustments of heading will appear. If the parameter is adjusted too low, the aircraft will leisurely responds
to heading deviations. Range of values of the parameter is from 1 to 24. Value 1 refers to low sensitivity, value 24 refers to high sensitivity.
Default value is 10.