Page 34
Autopilot Section
Pitch Axis Setup
Pitch Axis Setup
This submenu provides settings of the AP performance during controlled change of altitude.
•
Menu Pitch Axis Setup
•
Control Sensitivity
•
Mode-Vertical Speed
•
Mode-Longitudinal Angle
•
Max. Longitudinal Angle
•
Max. Climb Speed
•
Max. Descent Speed
•
Min. Air Speed
•
Max. Air Speed
Control Sensitivity
This parameter specifies how fast the AP reacts to deviations between target altitude and actual altitude. If the parameter is adjusted too high, the
aircraft will be itchy. Fast, hardline adjustments of altitude will appear. If the parameter is adjusted too low, the aircraft will leisurely responds to
altitude deviations. Range of values of the parameter is from 1 to 24. Value 1 refers to low sensitivity, value 24 refers to high sensitivity. Default
value is 10.Mode-Vertical Speed/Mode-Longitudinal Angle
These options are entitled here together because they are two options of one switch (metaphorically told). That means that you can choose Mode-
Vertical Speed or Mode-Longitudinal Angle.
Mode-Vertical Speed
If you select this mode, the AP will control the aircraft according to parameters Max. Climb Speed and Max. Descent Speed(both described
below).