Autopilot Section
Roll Axis Setup
Mode-Turn Rate/Mode-Bank Angle
These options are entitled here together because they are two options of one switch (metaphorically told). That means that you can choose Mode-
Turn Rate or Mode-Bank Angle.
Mode-Turn Rate
If you select this mode, the AP will control the aircraft according to parameter Turn Rate Target (described below) and Max. Bank
Angle(described below).
Mode-Bank Angle
If you select this mode, the AP will control the aircraft according to parameter Max. Bank Angle.
Max. Bank Angle
The parameter determines maximum bank angle of the aircraft during AP’s controlled turns. Range of adjustable values of the parameter is from
5 to 45 degrees. Default value is 15 degrees and it is adjustable in 1 degree increments.
Turn Rate Target
The parameter determines average target turn rate of the aircraft. Turn Rate target is specified in angular degrees per second. That means, for
example when Turn Rate Target is 1 degree per sec., then aircraft’s turn of 90 degrees will be performed in 90 seconds. Remember that
adjustable value of the parameter is only average value, which could be exceed due flight dynamics and the time for turn initialization. Range of
adjustable values is from 0.5 degree to 3 degrees per sec. Default value is 1.5 degree per sec. and it is adjustable in 0.1 degree per sec.
increments.