62
Installation
Setting up the machine base frame
TK Elevator
BA, TW45C | 6231003860 | 06/2022
6
Installation
6.1
Setting up the machine base frame
To reduce noise and sound transmission, we offer insulation elements that
can be inserted between the frame supports and floor. These differ according
to the type of mounting:
▪
A rubber block 100 x 100 x 50 high without base is used to mount the
drive on the machine room floor without a cement floor or directly sur-
face-mounted on the cement floor.
▪
For installation on cement floor, packing cast into cement floor (thickness
≤ 60 mm). The packing component must be cast in when installing the ce-
ment floor. A rubber block 100 x 100 x 50 with additional packing 140 x
140 x 80 mm is used here.
The number and arrangement of rubber elements is based on the total load
and the distance between the rope lengths (ASL dimension = distance
between rope departures). When arranging the supports, the overall centre of
gravity must lie within the rubber elements. The arrangement under the ma-
chine base frame should be such that the stress and/or buffering of the insu-
lation elements (maximum difference 3 - 5 mm) is as even as possible.
1. Loosely assemble the supplied frame in the machine room.
2. Mount the supports with additional drilled holes and pulley support on the
side of the diverter pulley.
3. Mount and secure the diverter pulley with axle on the pulley supports.
4. Position the frame in accordance with general arrangement drawing on
the insulation elements.
Fig. 31
ATR_2_21_0048_0
Содержание TW45C
Страница 1: ...OPERATING MANUAL TW45C Drive 06 2022 6231003860...
Страница 86: ......
Страница 140: ...PP0099019030 AFG 000 00 FR 13 07 2020 HEIMERDING D Ausdruck unterliegt nicht dem nderungsdienst...
Страница 145: ...145 TK Elevator BA TW45C 6231003860 06 2022...
Страница 146: ...146 TK Elevator BA TW45C 6231003860 06 2022...
Страница 147: ...147 TK Elevator BA TW45C 6231003860 06 2022...