Operating Instructions (continued from page 11)
13
12
counterclockwise to increase
rate of fire to the
desired speed.
clockwise
to slow the
rate of fire.
Tuning - Troubleshooting B:
If the trigger remains easy to pull after adjusting the flow control, there
may be a leak in the system. Double check installation making sure all
fittings are tight and o-rings are properly seated. If you need to
disassemble to check that all fittings are tight and o-rings are properly
seated (see Response
TM
parts below), do not disassemble this marker
Tuning - Troubleshooting A:
If tuning the Response
TM
Trigger produces little or no response in the
rate of fire, reset the Flow Control as follows:
1) With marker properly unloaded (see page 21), begin adjusting rate of
fire by turning flow control clockwise
completely (Do not over tighten
or damage will occur). In a safe direction fire 2 to 4 shots. Trigger should
become very hard to pull or even unable to be pulled. If this occurs, the
response trigger system is functioning properly. Go to step 2. If it does
not occur, go to Troubleshooting B.
2) Now while firing in a safe direction with marker still unloaded, slowly
turn the flow control adjustor counterclockwise
until desired rate of
fire is achieved.
NOTE: To disable the Response
TM
System:
❏
❏
❏
❏
❏
First follow the
unloading and air supply removal
instructions on page 20 and never
disassemble a marker that is under
pressure.
❏
❏
❏
❏
❏
Remove the banjo
fitting (20-20) attached to the power
tube/valve and replace it with the
shut off plug
(TA05021).
With a screwdriver, turn the Flow Control Adjustor to the desired speed.
TUNING THE RESPONSE
TM
TRIGGER RATE OF FIRE
another trigger pull. This time is measured in milliseconds. (The default Debounce
TM
setting is 20ms). If the marker has been double firing, increase the Debounce
TM
time. To make your marker fire faster, reduce the trigger response time by
decreasing the Debounce
TM
time. To adjust the Debounce
TM
time:
❏
Perform
STEP 3 1) then
❏
select the Debounce
TM
programming feature (= Solid Green
LED),
❏
❏
❏
❏
❏
pull and hold trigger until LED light goes out and
❏
❏
❏
❏
❏
release the trigger.
When LED comes back on -
❏
❏
❏
❏
❏
count the number of green flashes to determine
the current setting and once the LED stops flashing, you have 5 seconds to
begin
❏
❏
❏
❏
❏
pulling and releasing the trigger once for every FULL 1 ms of time you
want the Debounce
TM
to be. On each pull of the trigger, the LED will light up red
(indicating that the pull has been detected). Once you have pulled and released
the trigger the number of times necessary to set the function,
❏
❏
❏
❏
❏
wait a few
seconds for Programming Verification (See Programming Verification on page 11).
THE RATE OF FIRE (ROF) CAP troubleshooting and tuning/programming:
(ROF) Cap sets the maximum cycle speed of the marker. (The default ROF
Cap is 15 bps). Setting this value too low will reduce the usable speed of the
marker. Setting this value too high can cause misfires and “chops” if the hopper
can not keep up. To adjust the Rate of Fire cap:
❏
Perform STEP 3 1) then
❏
select the (ROF) programming feature (=Flickering Green LED),
❏
pull and
hold trigger until LED light goes out and
❏
release the trigger. When LED
comes back on -
❏
count the number of green flashes to determine the current
setting and once the LED stops flashing, you have 5 seconds to begin
❏
pulling
and releasing the trigger once for every bps you want the Rate of Fire (ROF) cap
to be. For example, 20 pulls/releases would be 20 bps. On each pull of the
trigger, the LED will light up red (indicating that the pull has been detected).
Once you have pulled and released the trigger the number of times necessary to
set the function,
❏
wait a few seconds for Programming Verification (See
Programming Verification on page 11).
To Perform A Complete E-Trigger
TM
Reset To the Default Settings:
With the E-Trigger turned off, press and hold the power button for 10 full seconds
as the LED turns on solid orange and at 10 seconds it turns solid red. At this
point, you release the power button and the LED will turn off and the board will
be reset to the factory default settings. Your marker is now ready for normal
operation with the Factory Default Mode Settings: Firing Mode = Semi-auto (1
pull/release of the trigger fires 1 time); Dwell = 6.0 ms; Debounce
TM
= 20 ms;
Rate of Fire (ROF) Cap = 15 bps.
NOTE: You can increase your 98 Custom
TM
Platinum Series
TM
Basic or 98 Custom
TM
Platinum Series
TM
Pro
TM
rate of fire by
adding a Cyclone
TM
Feeder Adapter to your marker.
The Cyclone
TM
Adapter works well with the E-Trigger
TM
markers.
Order the Cyclone
TM
Adapter Kit PN. T205030.
TA05021 Shut Off Plug
20-20 Banjo Fitting
TA0519 1/16”
Hose
02-103 Flow Control
20-04 90 Degree Fitting
20-19 1/8” Hose
20-05 Cylinder Fitting
20-02N RT Cylinder
Model Specific RESPONSE
TM
Parts Not
Shown on parts pages 14-19).
while it is pressurized with air, follow
disassembly / assembly instructions
on pages 21-23. If a problem still
exists, call Tippmann
®
Service
Department at 1-800-533-4831.
❏
Eye protection designed for paintball use must be worn by the user and