![Tibbo DS10x0 Скачать руководство пользователя страница 511](http://html.mh-extra.com/html/tibbo/ds10x0/ds10x0_programmable-hardware-manual_1114109511.webp)
500
Sensors (Probes)
© Tibbo Technology Inc.
BP#01
(ambient temperature
sensor)
- Measurement range: -40 to +125°C*;
- Measurement resolution: 0.25°C;
- Measurement accuracy: ±1°C.
BP#02
(ambient temperature and
humidity sensor)
-Temperature measurement:
-Measurement range: -25 to +50°C;
-Measurement resolution: 0.5°C;
-Measurement accuracy: not specified.
-Humidity measurement:
-Measurement range: 10 to 90%RH;
-Measurement resolution: 0.1%RH;
-Measurement accuracy: ±5%RH;
-Temperature range for valid humidity
measurements: +5 to +50°C.
BP#03
(ambient light sensor)
- Measurement range: 1 to 65528 lux;
- Measurement resolution: 1 lux;
- Measurement accuracy: 1 lux.
BP#04
(3-axis accelerometer)
- Independent X, Y, and Z axes;
- Measurement range for each axis: ±6G;
- Measurement resolution for each axis: 0.003G;
- Measurement accuracy for each axis: 0.1G.
Operating temperature
range
-40 to +85 degrees C
Operating relative
humidity
10-90%
Mechanical dimensions
(excluding terminal
blocks)
40.0 x 36.0 x 19.0 mm
* The actual measurement range is limited by the operating temperature range of
the Bus Probe itself, which is -40 to +125°C.
All specifications are subject to change without notice and are for reference only.
Tibbo assumes no responsibility for any errors in this Manual, and does not make
any commitment to update the information contained herein.
Think the above table should contain additional data? Do not just assume that you
know the answer — talk to Tibbo! Remember that the ultimate responsibility for all
decisions you make regarding the use and the mode of use of Tibbo products lies
with you, our Customer.