EXPLORER 122
User Manual
98-150578-A
4-2
Self Tests
Description
ENSM
Verifies that RF transceiver’s operational
state is FDD
Real Time Clock
Verifies the real time clock’s device id
Rx Synthesizer
Verifies that the RX PLL is locked
Tx Synthesizer
Verifies that the TX PLL is locked
Display Ethernet
Status
Displays the number of Ethernet packet
received and sent and the link status
Display Current OBIT
results
Displays result of the current online BIT
tests
Display POST Results Displays the result of the power-on self-
tests
4.2
Troubleshooting Guide
Faults may be detected by visual observation or by the built-in test (BIT). Problems
uncovered during preventive maintenance, or while the terminal is in service, their possible
cause, and recommended corrective action(s) are described in Table 5-2.
Table 4-2. Troubleshooting Guide
Problem/Observation
Possible Cause
Corrective Action
Cannot access terminal
web server
Terminal not powered on
Incorrect IP address
Cable is not plugged in
correctly
Default Ethernet IP address is
192.168.100.1
Default WLAN IP address is
192.168.200.1
Verify that cable is connected
to user device LAN port.
Verify the WLAN settings are
correct
Terminal not responding
to web server interface
Software error
Power Cycle Terminal