4-4
Faults may be visually observed as error codes on the Web MMI Status page as seen in Table
5-3. Web MMI Status.
Table 4-3. Web MMI Status
Fault Code
Description
Recommended Action
0x01 - 0x53
General fault
Reboot the terminal
0x61 - 0x63
Over temp fault
Place terminal in
environment less than
+70°C and power off until
terminal cools down
0x69 - 0x6B
Under temp fault
Place terminal in
environment greater than -
40°C until terminal warms
up
0x70 or other
Power fault
Reboot the terminal
4.3
Preventative Maintenance
Preventative maintenance is the systematic, scheduled care and inspection of equipment to
prevent equipment failure and to reduce downtime. The primary preventative maintenance
for the EXPLORER 122 Terminal is to keep the equipment clean. Use a soft brush, moist
sponge, and a clean cloth for this purpose. The radome should be visually inspected for any
attached substances, which could potentially obstruct functionality (e.g., mud on the
radome).
In addition, to ensure proper functionality and full operating potential of EXPLORER 122
Terminal capabilities, the unit should be visually inspected for cracks, corrosion, and loose
mating connector.
4.4
Warranty
For warranty information and repairs, please contact your service provider.
4.5
Serviceable Parts
The EXPLORER 122 Terminal contains no user-serviceable parts.