Withstanding Voltage
1.5 KV min
Spark Voltage
3 KV
A.3.4
Electrical Characteristics
Max. Conductor DC Resistance @20
°
C
87.6
Ω
/km (24AWG) / 23.2
Ω
/km (18AWG)
Max DC Resistance Unbalanced @20
°
C
5%
Maximum Pair-to-Pair Ground Capacitance
Unbalanced
330 pF / 100 m
Characteristic Impedance (1-100 MHz)
100
±
15
Ω
Frequency
100 MHz
Attenuation (Insertion Loss)*
24 dB
Characteristic Impedance
100
±
15
Ω
NEXT*
30.1 dB
PS-NEXT*
27.1 dB
ELFEXT*
17.4 dB
PS-ELFEXT*
14.4 dB
Return Loss*
20.1 dB / 100 m
Delay Skew*
45 ns / 100 m
*Min. at 100 MHz
A.4
Cable Assembly Steps
Use a utility knife to remove 12mm of the outer jacket of the cable and use diagonal cutters
to remove any shielding as shown in Figure A-1. Carefully remove 2-3mm of insulation from
the wires using a wire stripper. Avoid nicking the center conductor as you strip the insulation
from the wire. Ensure that the drain wire is at the same length as the other wires.