The operating input voltage range for the terminal is 10 to 30 VDC and draws a maximum of
4.8 amperes. If the application requires an extended cable length, it is necessary to calculate
the cable voltage drop to determine if the terminal is able to receive the minimum 10 volts
for operation. 18 AWG wire is recommended for both power and ground wires.
Exposure to outdoor elements can degrade the insulation of the cable and allow moisture to
penetrate the conductor and subsequently degrade the copper conductor. It’s highly
recommended that the cable chosen shall be able to withstand UV rays.
Cable shielding is a critical design element over long distance. The cable selection can
adversely be affected by EMI/RFI/ESI. The cable carries both power and Ethernet data. The
data lines should be twisted pair and shielded.
The recommended cable composition is described in the picture below. The overall cable
diameter should be less than 9.50 mm in order to fit in the connector backshell.